Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the marking „H07RN".
The printing of the type designation on the connection
cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of 16A (C) or 16A (K) for machines with a high
starting current (starting from 3000 watts)!
AC motor 230 V~ / 50 Hz
Mains voltage 230 V~ / 50 Hz.
Mains voltage and extension cables must be 3-lead = P
+ N + SL. - (1/N/PE).
Extension cables up tp 25m long must have a mini-
mum cross-section of 1.5 mm².
Mains fuse protection is 16 A maximum.
Three-phase motor 400 V~ / 50 Hz
Mains voltage 400 V~ / 50 Hz
Mains voltage and extension cables must be 5-lead
(3P + N + SL (3/N/PE).
Extension cables up tp 25m long must have a mini-
mum cross-section of 1.5 mm².
Mains fuse protection is 16 A maximum.
When connecting to the mains or relocating the ma-
chine, check the direction of rotation (swap polarity in
the wall socket if necessary). Turn pole inverter in the
machine socket.
12. Cleaning
Attention!
Pull out the power plug before carrying out any clean-
ing work on the equipment.
We recommend that you clean the equipment immedi-
ately after you use it.
Clean the equipment regularly with a damp cloth and
some soft soap. Do not use cleaning agents or sol-
vents; these may be aggressive to the plastic parts in
the equipment. Ensure that no water can get into the
interior of the equipment.
30 | GB
13. Transport
Move the splitter to the transport position beforehand.
See item 9.2, proceed in reverse order.
The log splitter is equipped with two transport wheels
and an additional transport wheel. Use the transport
handle (5) to move the splitter.
14. Storage
Store the device and its accessories in a dark, dry and
frost-proof place that is inaccessible to children. The
optimum storage temperature is between 5 and 30˚C.
Cover the electrical tool in order to protect it from dust
and moisture.
Store the operating manual with the electrical tool.
15. Maintenance
Attention!
Pull out the power plug before carrying out any mainte-
nance work on the equipment. Make sure that the drive
shaft is not connected to the traction unit.
When must the oil be changed?
First oil change after 50 operating hours, then every
250 operating hours.
Oil change (Fig. 14)
Bring the splitter to the transport position by tilting it
onto the transport wheels. Place a sufficiently large
container (at least 6 litres) under the drain plug on the
splitting column.
Open the drain plug (d) and carefully let the oil run into
the container.
Open the filling screw (c) on the top of the splitting col-
umn so the oil can drain more easily.
Replace the drain plug and its seal and tighten it.
Pour in fresh hydraulic oil (Contents: see Technical
data) and check the oil level with the dipstick. After
changing the oil, operate the kindling splitter a few
times without actually splitting.
Warning! Ensure that no debris gets into the oil
container.
Dispose of the used oil in a correct manner at a
public collection facility. It is prohibited to drop
old oil on the ground or to mix it with waste.
www.scheppach.com