FILLING UNIT
Be sure electrical cord is unplugged, and cleaning solution and heater coil are cool
before adding cleaning solution or performing any maintenance. Unit's thermostat has been factory set do
not attempt to change thermostat setting.
Remove stopper from drain.
Add about 30 gallons of cleaning solution, filling to the base of the sink.
Put center stopper back into drain opening.
OPERATING UNIT
Plug power cord into properly grounded circuit of the appropriate voltage.
Press TEST button on GFCI on power cord to ensure switch is operating properly. Press RESET button on GFCI to
prepare unit for operation.
Toggle "RESET" switch located under the electrical box. If the unit has an adequate level of cleaning solution in the
tank, the green "READY" light will illuminate.
If cleaning solution is not up to the set temperature and there is sufficient fluid in the tank, the heater will begin
operating. If the solution does not warm, unplug machine, and call factory.
Place stainless steel shelf on mounting ridges inside tank.
To operate the fluid pump, toggle "PUMP" switch on front of electrical box to the ON position.
For fluid flow through the flexible hose turn the directional valve pointing to hose. For fluid through the flow-thru brush
turn the directional valve pointing to brush. The center position will allow flow through both.
Unit is equipped with a low liquid level device which will shut off the pump and heater. If solution stops circulating and
the green light goes out, immediately turn off and unplug unit. Allow unit to cool and add more cleaning fluid.
Position hose so fluid does not splash out of sink or toward operator.
Make sure that drainage holes in sink are not obstructed.
Drainage holes will allow cleaning fluid to circulate back to base of unit to be reheated and filtered. If they become
obstructed, turn off pump and clear obstruction before continuing.
To return all fluid to base, remove stopper.
When sink is fully emptied, clean rubber strainer of any debris. Return to center drain before continuing to use unit.
55D600 (795-45486)