Descargar Imprimir esta página

Delta BRIZO MultiChoice T600 Serie Instrucciones De Instalación página 10

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation and Adjustment of the Temperature Knob
4
Failure to do so may cause injury.
1
5
6
Adjust temperature limit stop! Turn on water
supplies; let the water run at both full hot and
full cold to ensure the water is running as hot/
cold as possible. Place a thermometer in a
plastic tumbler, and hold the tumbler in the water
stream. Place the temperature knob (1) onto the
splines (2), then rotate the temperature knob
until you achieve your maximum desired
temperature from the outlet (not more than 120°
or the lower temperature mandated by your
local plumbing code). Remove the temperature
knob and replace onto the splines (2), making
sure that the temperature knob limit stop (3)
hits against the volume handle limit stop (4)
as shown. Secure the temperature knob using
screw (5) and place cap (6) on knob.
60 Series Maintenance
Faucet leaks from showerhead or tub spout:
SHUT OFF WATER SUPPLIES. Replace Cartridge
Assembly –Repair Kit RP47201.
84528
Rev. A
2
4
60 Series Installation
Siderna
®
10
13
12
11
®
(series T60X80) models, place
For Siderna
temperature handle (knob) (10) onto valve stem
and secure with screw (11). Ensure O-ring (12) is
assembled on handle cap (13). Install handle cap
by pressing it into place on top of the temperature
handle (10). Secure cap by tightening screw (14)
from the underside of the handle.
If water does not flow:
Verify that the hot side of the cartridge is installed
on the hot water supply line. If
it is not, turn off water supplies and
flip cartridge.
9
4
3
1
14

Publicidad

loading