pressure causes a hazardous
risk of bursting. Check the
manufacturer's maximum pressure
rating for air tools and accessories.
The regulator outlet pressure
must never exceed the maximum
pressure rating.
Customer Responsibilities
Check Safety Valve
Drain Tank
power is on. When performing
maintenance, you may be exposed
to voltage sources, compressed air,
or moving parts. Personal injuries
can occur. Before performing any
maintenance or repair, disconnect
power source from the compressor
and bleed off all air pressure.
NOTE: See "Operation" section for
the location of controls.
Risk of Bursting.
Too much air
MAINTENANCE
Before
each
use
Unit cycles
automatically when
How to Start:
1.
Set the On/Off switch to ON (I)
and allow tank pressure to build.
Motor will stop when tank pressure
reaches "cut-out" pressure.
2.
Pull the regulator knob out
and turn clockwise to increase
pressure. When the desired
pressure is reached push knob in
to lock in place.
The compressor is ready for use.
Daily
or after
each
use
To Check Safety Valve
properly, over-pressurization may
occur, causing air tank rupture or
an explosion.
1.
Before starting compressor, pull
the ring on the safety valve to
make sure that the safety valve
operates freely. If the valve
is stuck or does not operate
smoothly, it must be replaced
with the same type of valve.
13 - ENG
If the safety valve
does not work
A07982