7. Operating modes
In configurations with several actuators, the ''master'' must always be a chain actuator such as A1123.1,
A1123.2, A1123.3 and A1124.1
a. Single actuator mode (A1123.X) or (A1124.X)
Single actuator controllable via interlocked push buttons (*) or via gateway (refer to A1126 Gateway
User Manual).
b. Multiple mode (A1123.X + A1123.X+...) or (A1124.X + A1124.X+...)
2 to 4 actuators synchronously move a single window or several windows simultaneously, one or more
actuators defined as "slave" will follow the actuator defined as "master".
The command takes place via interlocked buttons (*) connected only to the "master". The command can
also be sent via gateway (refer to the A1126 Gateway User Manual).
The strokes of all actuators must all be set to the same length.
c. Combo mode (A1123.X + A1125.1) or (A1124.X + A1125.1)
If a chain actuator is used together with an electric lock on the same window, the "master" is necessarily the
chain actuator. The latter will receive the command.
The command takes place via interlocked buttons (*) connected only to the "master". The command can
also be sent via gateway (refer to the A1126 Gateway User Manual).
It is necessary to connect a magnetic reed-type sensor (code 1121.51) that prevents false operation
of the actuators when the window is open; without this sensor, it will not be possible to move the
actuators.
For the chain release manoeuvre from a closed window, keep the close button pressed for 5s. To
re-establish the vasistas operating condition, pull the sash tight so as to engage the magnetic reed and
press any button.e premere un qualsiasi pulsante.
* Interlocked buttons: code Master 1121.60