Possible defects
The following problems may occur during operation:
Disorder
Possible reasons
1. After commissioning, the
body of the water plant is not
yet full of water.
2. Insufficient tightness of the
supply pipe.
The pump is run-
3. The check valve is blocked.
ning but not pump-
4. The suction basket is not
ing water.
submerged
5. Defrost pipe air is not dis-
charged because the water
outlet is closed.
6. Elevation of intake (> 7 m).
1. It is without electricity supply.
The electric motor
2. Fan cover prevents rotation.
hums but does not
3. Blocked pump or motor
work.
damage
1. Suction height (> 7 m).
2. The suction basket is
Insufficient water
blocked.
flow.
3. Impurities reduced the effec-
tive performance of the device.
The heat sensitive
1. The pump is overloaded
switch does not
because there are impurities
turn off the device.
outside
Problem solving
1. Fill the device with water.
2. Check the recommended, used parts and
equipment components, such as inlet pipe joint,
discharge pipe joint, connecting ring, inlet pipe,
etc., also screw thread sealing strip made of
teflon or hemp rope.
3. Clean the filter and the main valve of the inlet
pipe.
4. When the device begins to suck, open the
water outlet (eg faucet, spray nozzles, etc.).
5. Lower the suction height.
6. Check the water level in the well or in the water
tank.
1. Check the power supply.
2. Pull out the fork, remove the fan cover with a
screwdriver, then reattach it. Gently rotate the
blade and check that it moves freely.
3. If it is blocked, send the device to an author-
ized service center.
1. Check the suction height.
2. Clean the filter.
3. Immerse the suction basket in deep water.
1. Clean the pump
2. Send the device to an authorized service
center for inspection.