SECURITY DISTANCES
From NOT combustible object :
•
A > 400 mm
−
From combustible object and from principal wall in rein forced concrete :
•
A > 800 mm
−
The minimal distance between the appliance and every flammable object around it is 1.5
•
meter.
1.4 Connection
Before connection check technical data reported in the technical plate ( Chap. 4 ) and
•
control that it correspond to the ones required in the order.
All heating biomass equipment especially wood appliance has to evacuate the
•
combustion products in a flue built in conformity with normative in force.
The following instructions describes „ informations for a good installation „ and it refers
•
to a normative in force but it are not to be consider exhaustive for installations laws.
B > 200 mm
C > 250 mm
B > 400 mm
C > 500 mm
23/88
IT IT IT IT- - - - EN
EN- - - - FR
FR- - - - E E E E S S S S mod. OMEGA EN13240
EN
EN
FR
FR
D > 1500 mm
D > 1500 mm
To measure from external side of
the equipment