Page 10
ENGLISH
A. Factory Wiring for 230VAC Supply
Wiring for
230VAC 60hz
Factory wiring 230VAC
- White Wire in 8 & 9
- Yellow Wire in 7
Figure 5.
Factory Wiring For 230VAC
The pump is factory wired for 230VAC supply power.
For 230VAC installations, do not make any adjustments
to the motor's factory wired terminal connections.
For use only with flexible wiring systems. Be careful
not to damage or abrade any of the wiring during this
procedure.
1.
Remove plug from conduit connection port. See Figure 4.
2.
Feed supply wires through conduit connection port.
3.
Wire electrical supply according to Figure 5.
4.
Secure conduit to the connection port with a 1/2" conduit
elbow or comparable conduit connection. See Figure 5.
Be careful not to damage or abrade any of the wiring.
5.
Secure the electrical housing cover using 4 screws.
See Figure 4.
4.3.4
Connect To Controls
The pump must be connected to a control so that:
•
The filtration pump is operating at all times the
booster pump is operating.
•
The booster pump is set to run after the filter pump
has been running for 30 minutes, and that it shuts off
30 minutes prior to the filter pump turning off.
4.4
Plumbing Connections
1.
Disconnect power to the filtration system at the breaker.
2.
Install a 2" PVC tee downstream from the filter and
upstream from any sanitation or chlorination equipment.
See Figure 7.
3.
Connect one leg of the tee to the pool return line.
Polaris
PB4SQ
Booster Pump | Installation and Operation Manual
®
™
L2
5
10
9
4
JUMPER
3
8
Y
2
7
L1
1
6
GND
B. Wiring for 115VAC Supply
Wiring For
115VAC 60hz
To change to 115VAC
- Move White Wire
from 9 to 10
- Move Yellow Wire
from 7 to 9
Figure 6.
Wiring For 115VAC
The pump is factory wired for 230VAC supply power.
Adjustments to the pump wiring are required in order
to accommodate this supply voltage. For use only with
flexible wiring systems. Be careful not to damage or
abrade any of the wiring during this procedure.
1.
Remove plug from conduit connection port. See Figure 4.
2.
Feed supply wires through conduit port.
3.
Rewire factory wiring and wire supply according to
Figure 6.
4.
Secure flexible conduit to conduit connection port with
a 1/2" conduit elbow or comparable conduit connection.
See Figure 6. Be careful not to damage or abrade any of
the wiring.
5.
Secure the electrical housing cover using 4 screws.
See Figure 4.
•
When using Jandy
automation, wire the booster
®
pump on the Aux 1 relay, and set the DIP switch S1-1
to on. The default label for this preset is "Cleaner"
and operating the booster pump on this relay under
this DIP switch setting will ensure that the filter pump
will work in coordination with the booster pump.
Please review all wiring and programming information
in the controls manual to ensure accurate control and
coordination between the filter pump and booster pump
settings.
4.
On the open leg of the tee install a PVC 2" to 3/4"
NPT reducer bushing. Be sure to use approved PVC
cement. DO NOT INSTALL with open leg facing up.
See Figure 7.
N
5
10
Y
4
9
JUMPER
3
8
2
7
L1
1
6
GND