Descargar Imprimir esta página

Enerpac BC1724Q Hoja De Instrucciones página 4

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 31
DESCRIPTION
Battery Charger
Battery
CHARGER SPECIFICATIONS
Model No.
Voltage
Frequency
Temperature Range
GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS
Power Adapters (B1724B and B1724Q Only)
The battery charger fully charges the WalkPac battery pack in approximately one hour.
Because the charger monitors the charge on the battery, the battery can be removed from
the charger at any time and replaced without starting the charging cycle from the
beginning. When recharged in the WalkPac battery charger, the battery will not exhibit
any residual "memory effect," and therefore, does not require full discharging before
recharging. Indicator lights on the front panel show the status of the battery: ready,
charging, temperature, or fault. If the battery is out of the temperature range, the charger
shuts off, resuming the charging cycle once the battery is within the proper temperature
range. If the battery has a fault, the charger shuts off.
The BP1724 battery pack is a 24 volt DC, 1.7 ampere/hour, rechargeable
Nickel-Cadmium battery, designed specifically for use with the WalkPac Portable Pump.
BC1724Q
100 VAC
NOTE: The temperature of the battery must be between 40°F [5°C]
and 105°F [40°C] to start the charging process.
Chargers should be grounded to reduce risk of electric shock. Charger is equipped with
an electric cord having an equipment-grounding conductor and a grounding plug. The
plug must be plugged into an outlet that is properly installed and grounded in accordance
with all local codes and ordinances.
These chargers have grounding plugs that look like the plug in Figure 1 (A.1.) on page 5.
A temporary adapter (C) shown in Figure 1 may be used with models B1724B and
B1724Q, if a properly grounded outlet is not available. The temporary adapter should be
used only until a properly grounded outlet can be installed by a qualified electrician.
DANGER
Before using the adapter as illustrated, be certain that the center
screw of the outlet plate is grounded. The green-colored rigid ear
or lug extending from the adapter must be connected to a properly
grounded outlet. MAKE CERTAIN IT IS GROUNDED. If necessary,
replace the original outlet cover plate screw with a longer screw
that will secure adapter ear or lug to outlet cover plate and make
ground connection to grounded outlet.
BC1724B
BC1724E
120 VAC
220 VAC
50/60 Hz
32°F - 122°F [0°C - 50°C]
4
BC1724I
240 VAC

Publicidad

loading

Este manual también es adecuado para:

Bc1724bBc1724eBc1724i