1.10 Troubleshooting
FAULT
Water drips out
when moving unit
Unit does not
operate
Unit operating, but
room not dry
Unit collects too
little water
If the problem you are experiencing is not listed here, contact our Service
Department toll-free at 800-932-3030 for further assistance.
LGR 6000Li Owner's Manual
CAUSE
Unit was
unplugged before
purging was
complete.
Unit not switched
on.
No power to
machine.
Not enough time to
dry.
Poor air movement
in room.
Excessive moist air
infiltration.
Room air is dry.
Room temperature
is too low.
Filter is clogged.
Coils are clogged.
SOLUTION
Purge unit before moving. See
THE END OF THE JOB
Switch unit on.
Plug in unit; check power cord
connection at wall outlet.
Make sure "Humidistat" is OFF.
Allow more time for drying.
Increase air movement with air
movers.
Seal off area to reduce infiltration.
Make sure "Humidistat" is OFF.
Confirm humidity level with
hygrometer.
Increase room temperature.
Check filter. Replace as necessary.
Check coils. Clean as necessary.
20