34.
Maintenance and care
Before any maintenance and cleaning work
Switch off the engine
Wait until the engine has come to a standstill
Disconnect spark plug connector (except when adjusting the idle speed)
Beware of rotating parts! Danger!
Due to the risk of fire, do not carry out maintenance work in the vicinity of open flame.
Maintenance and cleaning work not described in this chapter may only be carried out by customer
service.
Safety devices that have been removed for maintenance and cleaning must be properly checked
and reattached before use.
Only use original parts. Other parts may cause unforeseeable damage or pose a danger to the
user.
Maintenance
Wear gloves to avoid injury.
To ensure a long and reliable use of the device, carry out the following maintenance work
regularly.
Check the device for obvious defects such as
loose fastenings
worn or damaged components
Tank cap and fuel lines for their tightness
Check the device for wear after each use.
Clean or replace the air filter
Clean the air filter every 25 hours of operation or every 3 months to remove dust and dirt and to
prevent:
-performance losses,
-startup problems,
-too high fuel consumption
Clean the air filter approx. every 8 operating hours, or even more often in particularly dusty
conditions.
1. Set the starting lever (choke)
2. Remove the air filter cover 5 by opening the wing nut
3. Remove the foam air filter
4. Wash the air filter in lukewarm soapy water
Do not blow out the dirt, there is a danger of eye injuries!
to open, so that no dirt gets into the carburettor.