INSTRUCTIONS MANUAL
Ref. PE K5X 002
WIRELESS 1-CHANNEL SHUTTER/BLIND
ACTUATOR OR 2-CHANNEL SWITCHING
ACTUATOR WITH 2 INPUTS FOR PUSHBUTTONS
TECHNICAL DATA
Power supply
Output channels
Total output rating
Output switching rating
Motors
LED lamps
Incandescence &
230V Halogens
KNX Medium
Radio-Frequency
Transmission power
Application Software
Commissioning mode
Number of Inputs
Type of Input
Cable section
Dimensions
Working temperature
Storage temperature
Type of protection
According to
the Standard
Compatible with
DESCRIPTION
● KNX-RF S-Mode Switching Actuator which can work as:
- 2-Channel Switching actuator.
- 1-channel Blind/Shutter actuator.
● It has 2 inputs for conventional pushbutton, which can be configured
independently, through the ETS: Switching, Dimming, Blind/Shutter
Control, Scenes or Value sending.
CHARACTERISTICS
● The 2 outputs can be configured as:
- 1 blind/shutter channel: control of Roller Shutters/Awnings,
Venetian Blinds or Venting Louvers.
- 2 switching channels: control of 2 individual loads.
● In case it is configured as 1-channel blinds/shutters actuator, the
following alarms and functions are available: Wind alarm, Rain
alarm, Frost alarm, Sun Protection function, Scene control and
Forzed function.
● If it is configured as 2-channel switch actuator, the following
functions are available in each channel: Timer, Preset value, Scene
control, Logical functions, Forzed and Threshold function.
INSTALLATION
Work with electrical equipment on the 230V mains must
be carried out only by qualified technicians!
Switch off the mains before installing, removing or
handling of electrical equipment!
● Follow these steps for installation:
1) Connect the load and the power supply to the actuator following
one of the two wiring diagrams:
- Control of 2 independent loads
- Control of 1 Blind/Shutter
2) Connect the inputs to the conventional pushbuttons if it is
necessary
3) Switch-on the mains supply.
● Switch-on the mains supply. The range of the radio signal depends
on various external circumstances. The range can be optimised by
the choice of installation location avoiding placing it close to any
possible sources of interferences, e.g. metallic surfaces,
microwave ovens,...
COMMISSIONING
● Performance of the product is subject to the parameterization
made by ETS5.
You can download the application software from our website:
www.dinuy.com.
● For the commissioning of the actuator, follow these steps:
1) Supply the actuator. The red LED "Prog" goes on.
2) Allocate the physical adress and parameterize the application
software.
3) Press the programming key "Prog". The green programming LED
"Prog" will light up and it will be ready for loading the application
software into the device.
4) Load the physical address and the application software into the
actuator. The green LED "Prog" goes out.
5) If the actuator is not programmed 4 minutes after, the green LED
is swtiched-off and the device comes out from programming
mode. If programming is successful, the green LED is also
switched-off
RESET
● If there is any problem with the actuator, it is possible to do a
reset:
1 - Disconnect the 230V mains supply.
2 - Press and keep pressed the programming key "Prog".
3 - Connect again the 230V mains supply.
4 - Release the programming key "Prog".
CAUTIONS AND LIMITATIONS
● The mains supply must be protected according to existing rules.
- Electrical equipment must be installed and fitted by qualified
electricians only .
- Disconnect the mains to handle the load, replacing burned-out
lightbulbs, removing or adding new ones.
- Do not exceed the maximum load of the device.
ADVICES
● Avoid to install it close to radioelectrical devices, microwaves,...
● Leave a minimum separation of 2m between the transmitter and
the receiver.
● May be used for indoor installations in dry rooms only.
DINUY, S.A. Auzolan, 2, 20303, IRUN, SPAIN
WARNING: Hazardous voltage!
PE K5X 002
P2
P2
P1
PE K5X 002
P2
P2
P1
Declaration of conformity CE
www.dinuy.com
230V~ 50Hz
1 - Blind or 2 - ON/OFF
µ 16A / 250V
µ 16A / 250V
KNX RF 1.R
868,3MHz
< 10dBm
ETS5 or later
System Mode
Conventional Pushbutton
≤ 2,5mm2
46mm x 46mm x 30mm
-5ºC ~ +45ºC
-30ºC ~ +70ºC
IP20 (EN60529)
EN60669-2-1
IEC 14543-3
P1
C2
C1
L
N
L
N
P1
C2 C1
L
N
M
L
N
700VA
400W
3.000W
2