Direct Connection
The appliance must be connected directly to the mains using an omnipolar circuit breaker with a
minimum opening of 3 mm between the contacts.
The installer must ensure that the correct electrical connection has been made and that it complies
with the wiring diagram.
The cable must not be bent or compressed.
Regularly check the power plug and power cord for damage.
WARNING: This is a Class I appliance and MUST be earthed.
This appliance is supplied with a 3 core mains cable coloured as follows:
L or Live = Brown (or Red)
N or Neutral = Blue (or Black)
E or Earth
= Green and Yellow
N
L
This appliance requires a 32 Amp Miniature Circuit Breaker.
To avoid the risks that are always present when you use an electrical appliance it is important that
this appliance is installed correctly and that you read the safety instructions carefully to avoid misuse
and hazards. Please keep this instruction booklet for future reference and pass it on to any future
appliance but contact Customer Services.
The manufacturer declines all liability for damage caused to persons and objects due to incorrect
or improper installation of the appliance. Any permanent electrical installation must comply with the
contractor should undertake the electrical installation.
Technical data
Supply voltage
Dimensions (W x D x H)
Built-in dimensions
Max. power consumption
Type of hob
Number of cooking zones
and/or areas
3663602429517-Noname-A4-IM-SAFETY-V03.indd 7
N
L
N
L
(Blue)
(Brown)
(Green/Yellow)
Net weight
L
N
6000W (230V~ 50Hz)
Symbol
CLCER60a
Built-in hob
220-240V~
220-240 V~ 50Hz
590 x 520 x 52 mm
560 x 490 mm
7.6 kg
Value
4 zones
Unit
23/10/2018 4:56 PM