EU DECLARATION OF CONFORMITY
V2 SpA hereby declares that the products: FREDDY2
comply with the following directives:
99/05/CEE, ROHS-3 2015/863/EU
Racconigi, 01/07/2020
Legal representative of V2 S.p.A.
Sergio Biancheri
DISPOSAL
As for the installation operations, even at the end of this product's
life span, the dismantling operations must be carried out by
qualified experts.
This product is made up of various types of materials: some can
be recycled while others need to be disposed of.
Find out about the recycling or disposal systems envisaged by your
local regulations for this product category.
Important! – Parts of the product could contain pollutants or
hazardous substances which, if released into the environment,
could cause harmful effects to the environment itself as well as
to human health.
As indicated by the symbol opposite, throwing away this product
as domestic waste is strictly forbidden. So dispose of it as
differentiated waste, in accordance with your local regulations,
or return the product to the retailer when you purchase a new
equivalent product.
Important! – the local applicable regulations may envisage
heavy sanctions in the event of illegal disposal of this product.
PRODUCT DESCRIPTION AND
INTENDED USE
The receivers in this series are intended for controlling the
automation type door openers, gate openers and the like, lights
and electrical circuits in general.
Any other use is improper and prohibited!
Specifications:
Monostable, bistable or timer operating logic.
Possibility to select the contact type (N.A or N.C.) of the relay
1 through a dedicated jumper J1.
The contact of relay 2 is of N.A. type, to have an N.C. contact.
It is necessary to make changes to the hardware of the printed
circuit
It is possible to store up to 504 different codes with
self-learning mode
Memory full warning: the receiver blinks 15 times
Self-learning of transmitters managed by radio
RELAY CONTACTS
The contacts to the terminal board concerning the four relays are
of normally open (N.O.) type.
For a normally closed (N.C.) contact of relay 1, move the jumper
J1 to position 2 (Fig. 1).
For a normally closed contact (N.C.) of relay 2 short-circuit point
A with point B and cut the track at point C (Fig. 2) of the relay
concerned.
TECHNICAL DATA
Frequency
Power supply
Relay contacts
Temperature
Consumption
Sensibility
S/N
Size
Protection degree
PROGRAMMING
m
IMPORTANT: to memorize the code in the correct way
it is necessary to keep a minimum distance of 1,5 metres
between the transmitter and the receiver's antenna.
The self learning programming system enables the code
memorization and the setting of the following functioning modes:
MONOSTABLE: it activates the corresponding relay through the
time of TX transmission. When the transmission stops, the relay
goes automatically off.
BISTABLE: it activates the corresponding relay on the first TX
transmission. The relay goes off on the second transmission.
TIMER: the tx transmission activates the corresponding relay
which goes off after the set time (max 7,5 minutes).
SELECTION OF THE RECEIVER
CHANNEL
To select the channel of the receiver to be programmed, press
the P1 button for N times, as indicated in the table: the LED
corresponding to the selected channel turns on
SELECTED
CHANNEL
IMPULSES P1
CHANNEL 1
1
CHANNEL 2
2
PROGRAMMING OF THE MONOSTABLE
FUNCTION
1. Select the channel of the receiver to be programmed
2. Within 5 seconds, press and hold the button on the remote
control (about 2 sec.)
3. The led of the receiver goes out and goes on again: the code
has been memorised and the receiver remains standby for 5 s
with a new code to be memorised
4. Memorise all the remote control units necessary
5. After 5 seconds without a valid transmission, the led is turned
off and the receiver returns to normal operating mode
- 5 -
- 5 -
433,92 MHz
12 - 24 Vac / 12 - 36 Vdc
1A / 30Vdc
-20 ÷ +60°C
16 mA @ 24Vdc (stand by)
≥ -103 dBm
> 17dB @ 100dBm m=100%
132 x 26 x 74 mm
IP55
LED ON
L1
L2