User Manual
ELECTRONIC BATTERY CHARGER - OPERATING MANUAL
CONTROL COMPONENTS
The display shows:
Charging current (A)
•
Battery voltage (U)
•
Amp-Hours returned (C)
•
Elapsed time (h)
•
Active charge profile is displayed when button
•
To enter the charging parameter menu, see CHARGING SETTINGS.
•
OPERATION
Connect the AC power cable supplied with the battery charger to the charger. Connect the battery to the charger with
the correct polarity. Then, plug the AC power cord into the wall receptacle.
The LCD display of the battery charger will now show, in sequence, information related to the internal programming
of the charger: the software version installed on the charger (e.g. Ver 009.901.r09):
On the next screen, the LCD will display the parameters for:
At this point a test is conducted on the battery voltage to decide whether or not to start the charging process.
If the battery is not connected to the charger, the display shows " No Battery". This message remains on the display
as long as the test is unsuccessful. Same message is displayed in the case of:
If the battery test is still unsuccessful, the charger
continues to check the voltage on the battery cables until
it detects an acceptable condition.
8
is pressed.
Battery voltage,
•
Charging current,
•
Battery charger model,
•
Number and type of charging curve.
•
Reversed polarity
Battery in short circuit
Battery voltage lower than 3V.
D00240-02