5.
MENU
5.1 INSTALLER MENU
Access to this Menu is the RESPONSIBILITY of INSTALLATION TECHNICIANS or
EXPERT PERSONNEL, because the parameters shown, if modified, may render
the product is not suitable for the application in use.
• To access the MENU simultaneously press the keys K2 and K4 for about 3
seconds.
• To scroll through the parameters, use the keys K3 and K4
• To view the value of the parameter and enter for modification, press the key K2
• To change the value, press the keys K3 and K4
• To save the new value, press the key K2.
• To exit without saving, press the key K1
Press the K1 key again to exit from the Menu or wait 60 seconds
Descrizione
Fan Activation Air Thermostat
SAFETY Air Thermostat
ALARM Air Thermostat
FAN SAFETY Air Thermostat
Valve Opening Air Thermostat
Valve Closing Air Thermostat
SERVICE output Fan Activation Air
Thermostat
Temperature Range for Proportional
operation
Fan Activation hysteresis thermostat
SAFETY hysteresis thermostat
004723012 - 05/05/2022
ITALIANO
ENGLISH
Cod.
E01
E02
E03
E04
E05
E06
E07
E50
IE01
IE02
DEUTSCH
FRANÇAIS
Min
Set
Max
45
30
100
80
100
140
120
100
180
100
135
180
30
20
140
80
20
140
20
50
180
20
20
100
2
1
40
2
1
40
ESPAÑOL
U.O.M.
[°C]
[°C]
[°C]
[°C]
[°C]
[°C]
[°C]
[°C]
[°C]
[°C]
15