3.3
Fastening actuator on the valve
Actuator should be secured directly to the valve using proper bolts or via a
proper interface.
After assembly, the actuator can operate in any position.
However:
•
do not handle the actuator by handwheel to avoid damage on actuator
gearing.
•
cable glands must not be oriented upwards (loss of water tightness).
•
It is recommended not to position motor downwards.
4
ELECTRICAL COMMISSIONING
Ensure power wires are not supplied with electric power before wiring is
finished and the control compartment is closed.
!
If you need to open control compartment, previously cut off power supply to
the actuator.
4.1
Components (with cover open)
4
5
6
7
8
9
Actuator and its components are wired to internal terminal blocks.
1
9 – Cable entry plugs
8 – Ground terminal
7 – Heating resistor
6 – Terminal blocks
2
5 – Torque limiter
4 – Capacitor
3 – Modular reduction
gear
2 - End position cams
3
1 - Position indicator
12