Cyclic timer 12 VDC. It has a double time scale selectable by SW1 (scale A or B), ON and OFF time adjustable
independently between 0.1 seconds and 60 seconds. with potentiometers. Activation by Voltage.
Operation : When the power is connected, the timer activates the relay for the set ON time and deactivates the
relay for the set OFF time. This sequence repeats cyclically as long as the circuit is powered.
POWER SUPPLY : Connect the 12 VDC power supply to the POWER terminal, respecting the ± polarity. Install a
switch for circuit protection and your own safety, according to CE standard. Before activating the switch, make the
rest of the circuit connections.
To supply 230 V AC you can use our recommended FE-103 or FE-300 power supplies.
TIMING : To adjust the timing select the time scale with SW -1 , adjust ON time with potentiometer RV 1 , adjust
OFF time with potentiometer RV2 . Once these settings have been selected the timer is ready for use.
Timer activation : When the power is connected, the timer starts the ON-OFF work cycle.
Temporisateur cyclique 12V
Temporizador cíclico 12V
Temporitzador cíclic 12V
www.cebek.com
-
Cyclic timer 12V
I-10
Technical characteristics
Voltage : 12 V Dc
Medium Consumption : 60 mA
Timing configuration scale A : 0,1 to 6 secs.
Timing configuration scale B : 0,3 sec to 60 secs,
Activation : Voltage
Output type : Relay - NO / NC
Max. Output load : 7A ( 2A for inductive loads)
Operating Indicator Led : Yes.
Protection Inversion Polarity : Yes.
Sizes : 72 x 42 x 17 mm
Weight : 28,3 gr
Din rail : C-7562
sat@fadisel.com

Publicidad

loading

Resumen de contenidos para CEBEK I-10

  • Página 1 Cyclic timer 12V Temporisateur cyclique 12V Temporizador cíclico 12V Temporitzador cíclic 12V I-10 Technical characteristics Voltage : 12 V Dc Medium Consumption : 60 mA Timing configuration scale A : 0,1 to 6 secs. Timing configuration scale B : 0,3 sec to 60 secs,...
  • Página 2 I-10 Minuterie cyclique 12 VDC. Il dispose d'une double échelle de temps sélectionnable par SW1 (échelle A ou B), temps ON et OFF réglables indépendamment entre 0,1 seconde et 60 secondes. avec potentiomètres. Activation par tension. Fonctionnement : Lorsque l'alimentation est connectée, la minuterie active le relais pour le temps ON défini et désactive le relais pour le temps OFF défini.
  • Página 3 I-10 OUTPUT CONNECTION : The output is made by means of a relay, a device that admits any type of load that does not exceed 7A. The relay has three output terminals. The Normally open at rest (NO), the Normally closed at rest (NC), and the Common (CO).
  • Página 4 I-10 www.cebek.com sat@fadisel.com...