3.2
Scope of delivery
• Domestic hot water cylinder
• Technical documentation
The cylinder is delivered fully assembled.
▶ Check that the cylinder is complete and undamaged.
3.3
Product description
Pos.
Description
1
DHW outlet
2
Sensor pocket for temperature sensor, heat source
3
Heat source flow
4
Sensor pocket for temperature sensor, heat source
5
DHW circulation connection
6
Heat source return
7
Cold water inlet
8
Heat exchanger, enamelled smooth tube
9
Inspection aperture for maintenance and cleaning
10
Magnesium anode
11
Casing lid
12
Outer casing
Table 3 Product description (
3.4
Type plate
Pos.
Description
1
Type
2
Serial number
3
Useful capacity (overall)
4
Standby heat loss
5
Volume heated by immersion heater
6
Year of manufacture
7
Corrosion protection
8
Maximum DHW temperature
9
Maximum heating water flow temperature
10
Maximum solar flow temperature
11
Electrical power cable
12
Continuous output
13
Volumetric flow rate to reach continuous output
14
Volume with 40 °C draw-off temperature heated by immersion
heater
15
Maximum operating pressure on the domestic water side
16
Maximum design pressure (cold water)
17
Maximum operating pressure of heating water
18
Maximum operating pressure, solar side
19
Maximum operating pressure on the domestic water side (CH
only)
20
Maximum test pressure on the domestic water side (CH only)
21
Maximum DHW temperature with immersion heater
Table 4 Type plate
44
Fig. 1, page 65/Fig. 10, page 67)
3.5
Technical data
Dimensions and specifications
Pressure drop diagram
General information
Tilt height
Minimum room height for anode
replacement
Connection size, DHW
Connection size, cold water
Connection size, circulation
Temperature sensor inner
diameter
Inside diameter of handhole
Cylinder capacity
Useful capacity (overall)
Cylinder capacity V40
according to EN16147
Standby heat loss in accordance
1)
with DIN 4753 part 8
Maximum flow rate at cold water
inlet
Maximum DHW temperature
Maximum operating pressure,
potable water
Heat exchanger
Content
Surface area
Rating code N
according to DIN
L
2)
4708
Continuous output (at 80 °C
flow temperature, 45 °C DHW
outlet temperature and 10 °C
cold water temperature)
Heating water volumetric flow
rate
Heat-up time at 12 kW constant,
temperature difference 5 K from
35 °C to 60 °C
Maximum heating water
temperature
Maximum heating water
operating pressure
Connection size, heating water
1) Excluding distribution losses outside the cylinder.
2) Rating code N
=1 according to DIN 4708 for 3.5 persons, standard bath tub and
L
kitchen sink. Temperatures: cylinder 60 °C, DHW outlet temperature 45 °C and
cold water 10 °C. Measured at max. heat output. If the heat output is reduced, N
becomes smaller.
Table 5 Technical data
Unit WP 180 P1 B WP 300 KP1 B
 Fig. 2,
 Fig. 2,
-
page 65
page 65
 Fig. 3/ 3,
 Fig. 3/ 3,
-
page 66
page 66
mm
1343
1951
mm
2100
2100
DN
R1"
R1"
DN
R1"
R1"
DN
R¾ "
R¾ "
mm
19.5
19.5
mm
120
120
l
173.5
290.0
l
286
489
kWh/
1.15
1.52
24 h
L/min
14.5
20.1
°C
95
95
bar
10
10
(posit
ive)
l
11.5
11.5
2
m
1.69
1.69
N
1.6
8
L
kW
46.4
45.1
l/h
1140
1108
l/h
2600
2600
min
44
63
°C
95
95
bar
10
10
(posit
ive)
DN
R1"
R1"
Stora – 6721839992 (2022/07)