2.3. Parámetros técnicos de las unidades Xroom
2.3.1. Parámetros técnicos básicos
-
Parámetros técnicos básicos – Xroom-100 (XR1-010-ECxxHR...) – intercambiador de calor
Line
Type of recovery exchanger
pre-heater
Unit equipment
after heater
Nominal airflow/ BOOST*
Heat output (range) of heating**
Noise level**
Weight****
Water volume in exchanger
Power supply of the unit
Nominal input power of the unit /
Nominal current of the unit / BOOST*
Recovery efficiency
heat
per EN 308
humidity
Protection type
Energy efficiency class (ERP)
* BOOST mode - intensive ventilation for 10 minutes
Figura 4
** at the temperature gradient of 75/60 and an inlet air temperature of 20 °C
*** Sound pressure level in free space at a distance of 3 m
**** unit weight, without water and packaging
-
Parámetros técnicos básicos – Xroom-100 (XR1-010-ECxxER...) – intercambiador de entalpía
Line
Type of recovery exchanger
Unit equipment
after heater
Nominal airflow/ BOOST*
Heat output (range) of heating**
Noise level**
Weight****
Water volume in exchanger
Power supply of the unit
Nominal input power of the unit /
Nominal current of the unit / BOOST*
Recovery efficiency
heat
per EN 308
humidity
Protection type
Energy efficiency class (ERP)
* BOOST mode - intensive ventilation for 10 minutes
** at the temperature gradient of 75/60 and an inlet air temperature of 20 °C
*** Sound pressure level in free space at a distance of 3 m
**** unit weight, without water and packaging
Parámetros técnicos básicos – Xroom-250 (XR1-025-ECxxHR...) – intercambiador de calor
-
Versión 1 – GBR (23/06/2021)
XR1-010-ECS0HRX...XR1-010-ECV1HRX... XR1-010-ECE1HRX...XR1-010-ECS0HRP...XR1-010-ECV1HRP... XR1-010-ECE1HRP...
-
-
m3/h
kW
-
dB(A)
kg
16,3
l
-
V/Hz
W
30/167
A
0.3/1.32
%
%
-
IP
XR1-010-ECS0ERX... XR1-010-ECV1ERX... XR1-010-ECE1ERX... XR1-010-ECS0ERP... XR1-010-ECV1ERP... XR1-010-ECE1ERP...
pre-heater
-
-
m3/h
kW
-
dB(A)
kg
16,3
l
-
V/Hz
W
30/167
A
0.3/1.32
%
%
IP
HRV with temperature efficiency
-
-
electric
water
100/215
0.33 - 1.38
0,5
32,1
18,3
19,3
0,51
-
1 ~ 230 / 50-60
30/167
530/667
0.3/1.32
2.5/3.5
up to 87
-
-
20
cold climate A+, medium climate A, warm climate A
ERV with temperature and humidity efficiency
-
-
water
electric
90/205
0.29 - 1.24
0,5
32,1
18,3
19,3
0,51
-
1 ~ 230 / 50-60
30/167
530/667
0.3/1.32
2.5/3.5
up to 90
up to 85
20
cold climate A+, medium climate A, warm climate B
20
electric
electric
-
water
-
0.33 - 1.38
16,8
18,8
-
0,51
300/437
300/437
1.5/2.5
1.5/2.5
-
-
electric
electric
-
water
-
0.29 - 1.24
16,8
18,8
-
0,51
300/437
300/437
1.5/2.5
1.5/2.5
D-502-0152
electric
electric
0,5
19,8
-
800/937
3.7/4.7
-
Ficha 1
electric
electric
0,5
19,8
-
800/937
3.7/4.7
Ficha 2