Service
Service
Maintenance
Preventing ESD problems
The components inside the tool and controller are sensitive to electrostatic discharge. To avoid future mal-
function, make sure that service and maintenance is carried out in an ESD approved work environment.
The figure below shows an example of an appropriate service work station.
Service recommendations
Preventive maintenance is recommended at regular intervals. See the detailed information on preventive
maintenance. If the product is not working properly, take it out of service and inspect it.
If no detailed information about preventive maintenance is included, follow these general guidelines:
Clean appropriate parts accurately
Replace any defective or worn parts
Service instructions
Overhaul and preventive maintenance is recommended at regular intervals once per year or after maxi-
mum 250.000 tightening depending on which occurs sooner. More frequent overhaul may be needed if
used at high torque, high cycle rate or long tightening times. If the machine is not working properly, it
should immediately be taken away for inspection.
At the overhauls, all parts should be cleaned accurately and defective or worn parts (i.e. O-rings) should
be replaced.
Lubrication
Overhaul
Service must only be carried out by qualified personnel who have access to the Service instruction and/or
have been trained for service on Tensor ST Tools.
The electric motor is a sealed unit and may under no circumstances be opened by anyone else than Atlas
Copco Industrial Technique AB!
If it is judged that the electric motor is defect or in need of service, the complete motor unit should be re-
turned to Atlas Copco Tools for exchange.
Motors which have been opened by anyone else than Atlas Copco Tools will not be serviced.
Overhaul and preventive maintenance is recommended at regular intervals once per year or after maxi-
mum 250.000 tightening depending on which occurs sooner. More frequent overhaul may be needed if
the machine is used in heavy-duty operations. If the machine not is working properly, it should immedi-
ately be taken away for inspection.
When dismantling the tool always use the specially designed service tool 4080 0848 80, (two service
tools are required).