Descargar Imprimir esta página

OZU UM-004 Manual De Instrucciones página 16

Publicidad

Idiomas disponibles

Idiomas disponibles

Tabla 2. Estándares de cumplimiento
Phenomenon
Electrostatic
discharge
Radiated RF
EM elds1
Proximity
elds from RF
wireless
communication
equipment
Electrical
Fast/
Transients
bursts
Conducted
disturbances
induced by RF
elds.
Rated power
frequency
magnetic
elds
Basic
Immunity Test
Standard of
±8 KV contact
IEC 61000-4-2
±2 KV, ±4 KV,
±8 KV,±15KV air
3V/m
IEC 61000-4-3
80 MHz-2.7 GHz
80% AM at 1 KHz
See table
IEC 61000-4-3
±1 KV
IEC 61000-4-4
100 KHz repetition
frequency
IEC 61000-4-6
3V
0.15 MHz-80 MHz
6 Vm in ISM bands
between 0 .15 MHz
and 80 MHz
80% AM at 1KHz
30 A/m
IEC 61000-4-8
50 Hz or 60 Hz
ES - 15
Level of
±8 KV contact
± 2 K V, ± 4 K V,
± 8 KV, ±15KV air
3V/m
80 MHz-2.7 GHz
80% AM at 1 KHz
See table
±1 KV
100 KHz repetition
frequency
3V
0.15 MHz-80 MHz
6 Vm in ISM bands
between 0.15 MHz
and 80 MHz
80% AM at 1KHz
30 A/m
50 Hz or 60 Hz

Publicidad