9. Specifications

9.1 Specifications
Specifications
Measuring range
Overload safety
Vacuum-tight
Output signal
Permissible load in Ω
Current output (2-wire)
Voltage output (3-wire)
Power supply
Total current consumption
Response time (10 ... 90 %)
1)
Accuracy
Non-linearity (per EN 61298-2, BFSL)
Permissible temperature ranges
Ambient
Medium
Storage
Climate class
Storage
Transport
Operation
Vibration resistance
Shock resistance
IP ingress protection
16
Model MH-1
see product label
2 times
yes
see product label
≤ (power supply - 10 V) / 0.02 A
> 5 kΩ
DC 10 ...30 V
< 30 mA
≤ 5 ms
see order documentation
≤ ±0.4 % of span
-30 ... +85 °C
-40 ... +125 °C
-40 ... +85 °C
1K4 (per EN 60721-3-1)
2K3 (per EN 60721-3-2)
4K4H (per EN 60721-3-5)
20 g (per IEC 60068-2-6, under resonance)
500 g (per IEC 60068-2-27, mechanical)
see "Electrical connections"
WIKA operating instructions, pressure transmitter, model MH-1