Step 7. Turn the cover with the
o-ring back over and place in
the opening in the filter.
Step 8. Screw the lid onto the
top of the tank. Make sure the
lid is secure or the filter will
leak.
Step 9. Connect the UV
Clarifier into a properly grounded
electrical outlet.
Step 10. Wait several seconds then
check the indicator light to verify if
the UV bulb is functioning properly.
NOTE: This UV clarifier includes a
safety feature that will not allow the
light to turn on if the lamp holder
or locking ring are not securely
fastened.
Step 11. Unplug your pump from an
electrical source before connecting
tubing. Connect tubing from the
outlet of the pump to the inlet of
the filter (upper hole). Return water
to the pond by connecting tubing
to the outlet of the filter and to the
inlet of a water feature or return to
the pond. You can reconnect your
pump into a properly grounded
electrical outlet at this time.
Note: Pump and tubing are not
included.
Register your product online!
Use your smartphone camera
to scan the QR code or visit our
website totalpond.com/register
Item number:
#52236
8
Visit WWW.TOTALPOND.COM for information and tips.
7
8
C
D
A
A
9
GFCI
outlet
10
11
Date of purchase:
___ /___ /___
MAINTENANCE & TROUBLESHOOTING
Always disconnect units from the power source before
beginning any maintenance or work on the unit.
UV CLARIFIER
To maximize the performance of the UV clarifier, periodically
disassemble the filter to clean dirt and debris from the exterior
of the glass tube and inside light housing. Check the UV bulb
to make sure that it has nor burned out. Replace the bulb as
necessary, or after every season.
NOTE: Do not throw old bulb in normal trash receptacle. LAMP CONTAINS
MERCURY. Manage in accordance with disposal laws.
Visit www.lamprecycle.org or call 1-888-412-6001
Step 1. Disconnect the UV
Clarifier from the outlet.
Allow a sufficient time to pass
for the light to cool before
disassembling the light.
Step 2. Rotate the locking ring
counterclockwise to remove
the lamp holder.
Step 3. To replace the bulb,
remove the bulb holder.
Carefully remove the old bulb
by pulling firmly on the base.
Carefully install the new bulb
and put the bulb holder back
in place.
Step 4. Reinstall the lamp
holder and locking ring.
NOTE: This UV clarifier
includes a safety feature that
will not allow the light to
turn on if the lamp holder or
locking ring are not securely
fastened.
Step 5. Reconnect the UV Clarifier to
the power source.
Wait several seconds from the light to turn
on. Check the indicator light to varifiy if
the light is functioning correctly.
Please call Customer Care before returning item to store: 1-888-412-6001
2
lamp
lamp
locking
housing
holder
ring
3
new bulb
lamp
bulb
holder
old bulb
holder
4
lamp
lamp
locking
housing
holder
ring
5
9