INSTALLATION PROCEDURE - Connecting Hoses and Cords
Connector Connections
Remove the cover of the controller and
connect the sensor connector to the float
switch connector.
Connect the sensor connector and the hose
in the prescribed positions.
For single installation
Connect in one place.
Connector
(white) for sensor only
For double installation
Connect in two places.
Connectors
(white) and
(yellow) for sensor
For triple installation
Connect in three places.
Connectors
(white),
(yellow) and
(blue)
for sensor
Caution
All connectors of the sensors connected to the
spout are white.
The colors of the connectors arranged in the
controller are white, yellow and blue.
Different colors may be connected.
Wiring Image
Bundling of Float Switch Cord
Using bundling clamps, stow and bundle the cords.
Tank
Bundling clamp
(Continued)
Connect the hoses
and the sensors in
predetermined
White Yellow Blue
pairs.
Socket (Sensors)
Connector (Sensors, white)
Float switch
Side face (View of wiring)
10
INSTALLATION PROCEDURE - FILLING liquid soap
1. Remove cap on the tank.
2. Slowly pour liquid soap into the holding tank.
Please keep an eye on the level as you pour the
liquid soap in slowly so that it doesn't become
foamy. Please pour the liquid soap through the
build-in filter.
3. Firmly close the cap on the tank.
Please make sure that the cap is securely in place
after filling the tank.
Open
Close
11