3742540641-U-AFIA-BS11DC-V2
AUTOMATIC
OPERATION
CONFIGURATION
When the air conditioning system configuration is multisplit
and there is more than one indoor unit connected, the
automatic mode operates as follows:
- the first unit that switches on the system also decides the
operation mode (cooling or heating) for all the other units
that will be switched on after the first one;
- when the system has been switched on in cooling mode
and one unit is activated in heating mode, an error will be
signaled for this unit (wrong operating mode). If the same
unit is switched on in "automatic" mode and the desired
temperature is lower than the detected ambient
temperature, the unit will operate in cooling mode, like the
other units of the system; on the contrary, if the desired
temperature is higher than the detected one, the unit will
operate in fan mode;
- when the system has been switched on in heating mode
and one unit is activated in cooling mode, an error will be
signaled for this unit (wrong operating mode). If the same
unit is switched on in "automatic" mode and the desired
temperature is higher than the detected ambient
temperature, the unit will operate in heating mode, like
the other units of the system; on the contrary, if the desired
temperature is lower than the detected one, the unit will
operate in fan mode.
DEHUMIDIFYING (DRY)
1.Set the
button to DRY. The icon
2.Press the +/- buttons (temperature selection) to set the
desired temperature (the temperature range is between
32 °C max. and 10 °C min.).
NOTE
Dehumidifying operation is adjusted both by the difference
between set temperature and air temperature, and by the
value of relative humidity, detected by the sensor.
THE DISPLAY SHOWS THE
SELECTED TEMPERATURE.
NOTE
Use DRY operation when you want to reduce the humidity
l
in the room.
During DRY operation, the fan speed is automatically set
l
(Remote control lamp
Dry operation is not possible if the indoor temperature is
l
10 °C or less.
FAN ONLY
If you want to make air circulate without any temperature
control, press
button until only the
appears on the display.
20-07-2015
8:46
IN
MULTISPLIT
is displayed.
AFTER 5 SECONDS FROM THE
REQUIRED TEMPERATURE SETTING
THE DISPLAY WILL SHOW THE ROOM
TEMPERATURE AGAIN.
is ON) to prevent overcooling.
fan symbol
Pagina 7
ADJUSTING THE FAN SPEED
AUTOMATIC
Simply set the FAN selector to the
microcomputer automatically controls the fan speed when
the AUTO mode is selected. When the air conditioner starts
operating, in heating or cooling, the fan speed varies (high
- medium - low - very low) according to the thermal load of
the room.
NOTE
The automatic speed is not available in FAN ONLY mode.
MANUAL
If you want to manually adjust speed just set the FAN selector
as desired.
High speed
Med. speed
CLEAN/FILTER Ti0
2
Pressing the
button (symbol
the filtering system with titanium dioxide is activated; this
is very effective to prevent bad odours and to eliminate
bacteria and micro-organisms.
NOTE
The filter is active only if the internal fan is operating.
NIGHT MODE / ENERGY SAVING
This mode enables you to save energy.
l
1. Set the
or
selector to cool, dry or heat.
2. Press the
button.
3. The
mark appears on the display. Press the
button again to release the function.
What does the NIGHT mode mean?
When you select the NIGHT mode, the air conditioner will
modify automatically the set temperature after 60 minutes.
This enables you to save energy without sacrificing your
comfort.
OPERATING MODE
SET TEMPERATURE CHANGE
Heating
Cooling and Dry
NOTA
During the NIGHT mode the internal fan speed is
automatically lowered and reduces the noise.
7
position.A
EG
Low speed
on the display)
Lowered by 2 °C
Raised by 1 °C

Publicidad

loading

Este manual también es adecuado para:

Afibs11dc v2