Descargar Imprimir esta página

Comunello CU-230V-1M Instrucciones De Uso Y De Instalacion página 16

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 31
Deletion.
Use SELECT to go to LED L3; activate blinking of the code to be deleted
(CODE or PEDESTRIAN identified by the respective blinking); press and
hold down SET for > 5 s. After this interval the LED will switch off for 2
seconds and the procedure is completed. If all CODE and PEDESTRIAN
codes are deleted, the LED will remain off.
If only PEDESTRIAN codes remain stored, the LED blinking mode will
change (1 1 1 1 0 1 1 1 1 0)
Rule of the first saved Remote control:
When programming remotes the following rule is applied: if the first remote
to be saved is of the rolling code type, the receiver will subsequently
accept only rolling code remotes, thus providing enhanced anti-intrusion
security; if the first remote to be saved is a fixed code type, the receiver will
subsequently accept both fixed code remotes and rolling code remotes,
although only the fixed part of the latter will be controlled (thus effectively
relinquishing the security of the rolling code system).
IMPORTANT: Whenever a reset is performed the receiver is restored to the
factory settings so the first remote rule logic will be reset.
4. CONDO:
The Condominium function means that during the opening movement or
during the pause time the control unit will not respond to commands sent
by Pushbuttons or remotes. In contrast, during the closing movement a
command sent by the Pushbuttons or the remotes will reverse the direction
of movement. This operating mode is invaluable when the automation
includes a loop detector. In the default configuration the control unit is set
with the Condominium function disabled; if the Condominium function is
required, proceed as follows: use the SELECT key to select blinking LED L4
and then press the SET key: LED L4 becomes steady on and programming
will be completed. Repeat the procedure if you wish to restore the previous
configuration.
5. MOTOR TIME:
(Programming of the motor run time with max 4 minutes). The control unit
is factory set with a preset motor time of 30 seconds without deceleration.
If motor time must be changed, programming must be carried out with the
gate closed as follows: use the SELECT key to select blinking LED L5 and
then press the SET key momentarily; the operator will start the opening
movement; when the required deceleration starting point is reached
press the SET key again; at the same time the operator will decelerate
and reach the required position; press SET to terminate the opening cycle.
Thereafter LED L5 will start blinking rapidly; now repeat the motor time and
deceleration programming procedure for the closing cycle. If you do not
require the control unit to perform the deceleration, during programming,
when the open-close cycle has been completed press the SET key twice
consecutively rather than just once. During programming, instead of the
SET key on the control unit you can use the button on the remote, providing
the remote has been saved beforehand.
6. PAUSE TIME:
(Automatic closing time programming 4 min. max.) The control unit is
factory set with automatic closing disabled. If you wish to enable automatic
closing proceed as follows: use the SELECT key to select blinking LED L6
and press the SET key momentarily; now wait for a time equivalent to the
required time; press the SET key again momentarily and at the same time
the automatic closing time will be saved and LED L6 will remain steady on. If
you wish to restore the initial condition (no automatic closing) select blinking
LED L6 and then press the SET key twice consecutively in a time period
of 2 seconds. The LED will switch off and the operation will be completed.
During programming, instead of the SET key on the control unit you can use
the button on the remote, providing the remote has been saved beforehand
7. AUTO PROGRAM:
The control unit offers the facility of Automatic Programming (SIMPLIFIED).
First bring the gate leaves to an intermediate position, use the SELECT
key to select blinking LED L7 and then hold down the SET key; the control
unit executes the Auto programming procedure by performing a complete
open-close cycle (keep the SET key pressed until Auto Programming is
completed). During the Auto Programming procedure the Deceleration
cycle is set automatically at approximately 15% of the complete cycle.
During Automatic Programming, instead of the SET key on the control unit
you can use the button on the remote, providing the remote has been
saved beforehand.
EXTENDED MENU 1
The control unit is factory set to allow direct selection exclusively of the main
menu functions. If you wish to enable the functions described in Extended
16
COMUNELLO ®Copyright 2014 - All right reserved
Menu 1, proceed as follows: select blinking LEV LED and press SET once.
The LED will start blinking. This means there will be 30 seconds to select
the functions of Extended Menu 1 using the SELECT and SET keys; once
an additional 30 seconds have elapsed the control unit reverts to the main
menu.
L1
FOTOTEST
L2
PEDESTRIAN TIME
L3
DECELERATION
L4
ELEC BRAKE
L5
RELEASE STROKE
L6
SLAM LOCK
L7
COURTESY LIGHT
LEV
MENU
1. FOTOTEST: (Photocells test)
The control unit is factory set with the photocells test disabled. To enable the
test, proceed as follows: make sure you have enabled Extended Menu 1,
use the SELECT key to select blinking LED L1 then press the SET key, LED
L1 becomes steady on and the programming procedure will be completed.
Repeat the procedure if you wish to restore the prior configuration.
2. PED. MOT. T: (Programming of pedestrian motor time, 4 minutes
max).
The control unit is factory set with a preset Motor time (Pedestrian) of
10 seconds without deceleration. If the pedestrian motor time must
be changed, programming must be carried out with the gate closed as
follows: make sure you have enabled Extended Menu 1, use the SELECT
key to select blinking LED L2, then press the SET key momentarily; the
Operator will start an Opening cycle; when the gate reaches the required
initial deceleration point press the SET key again: LED L2 will start blinking
more slowly and the Operator performs the deceleration; when the required
position is reached press the SET key to terminate the Opening cycle. At
this point LED L2 returns to the normal blinking speed and the Operator
restarts in the Closing movement; repeat the operations described above
for the Closing movement. If you do not require the control unit to perform
the deceleration, during programming, when the open-close cycle has
been completed press the SET key twice consecutively rather than just
once. During programming, instead of the SET key on the control unit you
can use the button on the remote, providing the remote has been saved
beforehand.
3. DECELERATION:
As mentioned earlier, the control unit allows programming of a deceleration
stage during opening and closing. However, if no deceleration is required,
this stage can be inhibited. If, before excluding the deceleration stage it had
already been programmed using the Motor Times Programming function,
programming must be repeated from the beginning. If the deceleration
stage is to be excluded proceed as follows: make sure you have enabled
Extended Menu 1, use the SELECT key to select blinking LED L3 and
then press the SET key: LED L3 becomes steady on and programming will
be completed. Repeat the procedure if you wish to restore the previous
configuration.
4 ELECTRONIC BRAKE:
The control unit is factory set with the electronic brake function disabled.
To enable the function, proceed as follows: make sure you have enabled
Extended Menu 1, use the SELECT key to select blinking LED L4 then
press the SET key, LED L4 becomes steady on and the programming
procedure will be completed.
With this function enabled the control unit reduces coasting of the gate due
to inertia at the time of a stop or direction reversal command. Repeat the
procedure if you wish to restore the previous configuration.
5 RELEASE STROKE:
The control unit is factory set with the release stroke function disabled. To
enable the Release Stroke function at maximum power, proceed as follows:
make sure you have enabled Extended Menu 1, use the SELECT key to
select blinking LED L5 then press the SET key, LED L5 becomes steady on
and the programming procedure will be completed. If you wish to enable
the Release Stroke function at the power set with the "FORCE" trimmer,
repeat the procedure described above,
press the SELECT key twice (LED L5 will blink rapidly) rather than just once.
Repeat the procedure if you wish to restore the initial configuration.
This procedure makes it possible to facilitate release of the gate lock and
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
1 FLASH

Publicidad

loading