product. Leave the door open to thoroughly dry the inside of the refrigeration chamber. Close the door after drying is fi nished.
Product when stored should be kept indoors, protect it from dust, dirt and moisture. It is recommended to store the product in its
original packaging.
Store the product in its working position. Do not tilt, do not store products in layers. Do not put anything on the product.
Removal of failures
Find below the typical defects, their causes and possible solutions. In case of any doubts, stop using the product, disconnect it
from power supply and contact the authorized service center of the manufacturer.
Failure
Device does not start
Device starts, but the temperature
is too low / too high
Water leaks from the device
Device is excessively loud
TECHNICAL DATA
Parameter
Catalogue number
Rated voltage
Rated frequency
Rated current
Rated power
Insulation class
Climatic class
LED lamp power
Operating temperature
Rated capacity
Coolant (type / weight)
Insulation foaming agent
Net weight
Noise level
- acoustic pressure LpA ± K
- power LwA ± K
Max. load on shelves / containers GN
Parameter
Catalogue number
Rated voltage
Rated frequency
O R I G I N A L
16
Possible cause
Device was not switched on
Plug or cable were damaged
Power failure.
Damage of internal wiring
Too much ice on the evaporator
Condenser is locked by dust
Improperly closed door
Device placed too close to heat source or fl ow of
air around the condenser was disrupted
Too high ambient temperature
Improper foodstuff s placed in refrigeration
chamber
Device overloaded
Device was not levelled
Drainage outlet was blocked
Disrupted water outfl ow
Damaged water container
Water container overfl own
Loosen screws or nuts
Device has not been levelled or it stands
unstably
Measuring unit
YG-05250
[V~]
220-240
[Hz]
50
[A]
2
[W]
215
I
4
[W]
-
[
C]
-2/+8
O
[l]
282
R290 70g
C5H10
[kg]
102
[dI(A)]
< 70
[dI(A)]
< 80
[kg]
40
Measuring unit
YG-05275
[V~]
220-240
[Hz]
50
GB
Problem solution
Check if the device has been properly connected and switched on using
the switch
Contact the authorised service
Check the power supply
Contact the authorised service
Defrost the device
Contact the authorised service
Check if the door was closed and its seal is undamaged
Change the location of device
Increase effi ciency of ventilation or displace the device to cooler location
Remove excessively warm food, check if the food does not block the fans
Reduce quantity of foodstuff s inside the device.
Level the device
Clean the outlet
Clean the fl oor of the device
Contact the authorised service
Empty the water container
Check and tighten screws and nuts
Check the position of the product and change it if necessary.
Value
YG-05251
YG-05255
YG-05256
220-240
220-240
220-240
50
50
50
4
2
4
520
230
560
I
I
4
4
4
-
-
-
-18/-22
-2/+8
-18/-22
282
417
417
R290 95g
R290 70g
R290 95g
C5H10
C5H10
C5H10
110
134
159
< 70
< 70
< 70
< 80
< 80
< 80
40
40
40
Value
YG-05280
YG-05290
YG-05300
220-240
220-240
220-240
50
50
I N S T R U C T I O N S
YG-05260
YG-05262
220-240
220-240
50
50
1.2
1.2
170
170
I
I
I
4
4
-
-
+2 / +8
+2 / +8
240
240
R600A 65g
R600A 65g
C5H10
C5H10
76
70
< 70
< 70
< 80
< 80
40
40
YG-05305A
220-240
50
50
YG-05270
220-240
50
1.2
170
I
4
-
+2 / +8
240
R600A 65g
C5H10
75
< 70
< 80
40
YG-05310
220-240
50