4
Technical data
4.1
Technical data
When powered by a generator or transformer, the generator or transformer's power output must be at
least twice the rated input power shown on the rating plate of the electric tool. The operating voltage
of the transformer or generator must always be within +5% and -15% of the rated voltage of the
electric tool.
The information given applies to a rated voltage of 230 V. The data may vary in the event of deviations
from the rated voltage and for country-specific versions. Please refer to the electric tool's type
identification plate for details of its voltage, frequency, current and input power ratings.
Weight
Single impact energy
Drilling diameter range in
concrete/masonry (hammer drill bit)
Drilling diameter range in wood (solid)
Drilling diameter range in metal (solid-
head drill bit)
Storage temperature
Ambient temperature for operation
4.2
Noise information and vibration values in accordance with EN 62841
The sound pressure and vibration values given in these instructions were measured in accordance with a
standardized test and can be used to compare one power tool with another. They can also be used for a
preliminary assessment of exposure.
The data given represent the main applications of the power tool. However, if the power tool is used for
different applications, with different accessory tools, or is poorly maintained, the data can vary. This can
significantly increase exposure over the total working period.
An accurate estimation of exposure should also take into account the times when the power tool is switched
off, or when it is running but not actually being used for a job. This can significantly reduce exposure over
the total working period.
Identify additional safety measures to protect the operator from the effects of noise and/or vibration, for
example: maintaining the power tool and accessory tools, keeping the hands warm, organization of work
patterns.
Noise emission values
Sound power level (L
WA
Uncertainty for the sound power level (K
Emission sound pressure level (L
Uncertainty for the sound pressure level
(K
)
pA
Total vibration
Chiseling (a
)
h, Cheq
Hammer drilling in concrete (a
Drilling in metal (a
)
h, D
Uncertainty for the given vibration value (K)
6
English
TE 3-ML
3.1 kg
2.1 J
4 mm ... 28 mm
1.5 mm ... 20 mm
1.5 mm ... 13 mm
−20 ℃ ... 70 ℃
−17 ℃ ... 60 ℃
)
)
WA
)
pA
)
h, HD
TE 3-ML
101 dB(A)
3 dB(A)
90 dB(A)
3 dB(A)
TE 3-ML
12.2 m/s²
15.6 m/s²
5.0 m/s²
1.5 m/s²
2121691
TE 3-CL
3.0 kg
2.1 J
4 mm ... 28 mm
1.5 mm ... 20 mm
1.5 mm ... 13 mm
−20 ℃ ... 70 ℃
−17 ℃ ... 60 ℃
TE 3-CL
101 dB(A)
3 dB(A)
90 dB(A)
3 dB(A)
TE 3-CL
11.2 m/s²
14.6 m/s²
5.0 m/s²
1.5 m/s²
*2121691*