WIKA RLS-1000 Manual De Instrucciones página 12

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5. Commissioning, operation
Ensure that the sealing faces of the vessel or float switch are clean and
do not show any mechanical damage.
EN
5.2 Mounting
Observe the torque values of screws specified in pipefitting work.
In the selection of the mounting material (sealings, screws, washers
and nuts), take the process conditions into account. The suitability
of the sealing must be specified with regard to the medium and
its vapours. In addition, ensure it has corresponding corrosion
resistance.
Mount the float switch either via mounting thread  or mounting
flange (not illustrated).
The guide tube  should not be inclined more than a maximum of
30° to the vertical.
If the geometry of the float does not fit through the process
connection, the float must be removed before mounting.
- For this, before removal, mark
the position of the float stops
 with a waterproof pen
- Mark the mounting position of
the floats (e.g. "Up")
- After the float switch has been
mounted, the float should be
re-attached within the inside of
the tank (pay attention to the
mounting position!).
- Float stops  must then be
re-attached at the marked
points.
The number of floats and also
the position of the float stops are
dependent upon the dimension
and the number of switch points.
12
WIKA operating instructions models RLS
≤ 30°

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rls-2000Rls-3000Rls-5000Rls-6000

Tabla de contenido