Descargar Imprimir esta página

Firman H05753 Manual Del Usuario página 25

Publicidad

Idiomas disponibles

Idiomas disponibles

8. Move the choke lever to the "RUN" position.
9. Allow generator to run at no load for few
minutes upon each initial start-up to permit
engine and generator to stablize.
Starting the Generator (Electric Start-LPG)
1. Before starting the generator, check for loose
or missing parts and for any damage which
may have occurred during shipment.
2. Check oil level .
3. Connect the regulator to both LPG cylinder and
generator.
NOTE: Do not place LPG cylinder in the path of muffler outlet.
4. Fully open the LPG cylinder knob.
5. Turn the fuel selector switch to "LPG" position.
English
NOTE: When the fuel selector switch is turned
to the "LPG" position, the indicator light will
become RED up to 4 minutes(before goes off).
Starting the engine successfully during these
4 minutes will turn the indicator light GREEN.
6. Disconnect all electrical loads from the
generator. Never start or stop the generator
with electrical devices plugged in or turned
on.
7. Move choke lever located on engine to "START"
position.
8. Flip the engine switch to the "START"(ll) position
for few seconds and then release.
REMINDER: MUST HAVE SOLID RED INDICATOR
LIGHT TO BE ABLE TO START THE GENERATOR.
THE GENERATOR CANNOT BE STARTED DURING
BATTERY POWER SAVING MODE UNLESS
THE FUEL SELECTOR SWITCH IS TURNED TO
THE "OFF" POSITION AND THEN TURNED
BACK TO THE "LPG" POSITION.
See Indicator light-Battery power Saving
Mode section for more information.
9. Move the choke lever to the "RUN" position.
Page 23
3 sec.
Customer Service: 1-844-FIRMAN1

Publicidad

loading