Descargar Imprimir esta página

GE AHS24 Manual Del Propietario Y Instrucciones De Instalación página 15

Publicidad

Idiomas disponibles

Idiomas disponibles

Through-the-Wall Installation Instructions—Optional
The case may be installed through-the-wall
in both existing and new construction.
Read completely, then follow step-by-step.
NOTE: Obtain all materials locally for
mounting the air conditioner through-the-
wall.
1. IMPORTANT
Through-the-wall installation is not
appropriate if any of the side or top louvers
in the case will be obstructed by the wall.
All side and top louvers in the case must
project on the outdoor side of the wall.
The room side of the case must project
into the room far enough to maximize the
balance of the unit.
The case must be installed level from side-
to-side and with a slight tilt from front to
rear. Use a level; no more than a 1/2 bubble
will be the correct case slant to the outside.
Lintel angle is required to support bricks or
blocks above opening.
Flashing is required and should extend the
length of the opening to ensure no inside
cavity leakage occurs.
A. Remove the air conditioner from the case.
For specific instruction, refer to the Window
Installation Instructions.
B. Make certain that a wall receptacle is
available close to the hole location or make
arrangements to install a receptacle.
C. Place the case in the wall opening and
place wood support strips between the case
bottom and the flashing on both sides of the
bottom rail. They should be the same height as
the bottom rail and the same length as the wall
opening.
49-7791
1. IMPORTANT
D. Secure with 14 wood screws anchored at least
an inch into the wall support structure.
NOTE: Drill pilot holes, if necessary, for proper
installation. If the frame is oversized, use shims
to prevent case distortion.
2. FINISH THE WALL OPENING
A. Caulk all four sides on the outdoor side of the
case to prevent moisture from getting through
further prevent water from dripping inside the
wall and down the outside of the building.
Caulking
Air louvers
(top and sides
must project
on the outdoor
side of the
wall)
Wood filler and
caulking (above
and below the
flashing)
Flashing
(Drip rail)
Flashing
(Drip rail)
B. Place the air conditioner into the case.
For specific instruction, refer to the Window
Installation Instructions.
(cont.)
Plaster line
Trim molding (if
desired)
INSIDE
Case
bottom
rail
Wood support strips

Publicidad

loading