Installation
3.
2 h
Electrical connection
Before each connection check if:
▶ power supply, socket and fusing are appropriate to the rating plate.
▶ the power socket is earthed and no multi-plug or extension.
▶ the power plug and socket are strictly according.
Connect the plug to a properly installed household socket.
28
3. The stability can be checked by alternately bump-
ing on the diagonals. The slightly swaying should
be the same in both directions. Otherwise the
frame can warp; possible leaking door seals are
the result. A low tendency to the rear facilitates
the closing of the doors.
Fine tuning of the doors
If the doors are not in one level, this mismatch can be
remedied by following:
Using adjustable foot
Rotate the adjustable foot according to the direction
of arrow to turn up or down the foot.
Contact after-sale service if needed.
Notice:
In the future use of refrigerator, doors une-
ven phenomenon may occur to the weight of
stored food. Then please adjust according to
the above methods.
Waiting time
To the maintenance-free lubrication oil is located in
the capsule of the compressor. This oil can get through
the closed pipe system during slanting transport. Be-
fore connecting the appliance to the power supply you
have to wait at least 2 hours so that the oil runs back
into the capsule.
GB