It is strictly to pay attention that water does not get into the motor.
After an interruption of work first see for yourself that the core bit turns loosely before you start the
machine again.
Wear ear protection when working with this machine.
Wear work gloves when using the core drill. Gearbox, motor and handle become hot during operation.
3.
T E C H N I C A L D E S C R I P T I O N
The DME17DP is a dry core drilling machine, which is operated without water supply. It can be used
both in a drill stand and as a hand-held core drilling machine.
The switch-on and switch-off soft-beat function accelerates work progress in reinforced concrete and
hard materials. The drilling dust is removed from the diamond segments by the soft beat and removed
by the efficient dust extraction system.
The boring tool (4) consists of a tube with an appropriate tool adapter 1 1/4" UNC, and with soldered-
on or welded-on diamond segments.
The machine may not be used for a different purpose or with a different tool.
3.1
Technical Data
Type
Rated Voltage
Rated Current
Power input
Power output
Frequency
Rated Speeds (Rated Load) 1/min
Beat frequency
Beat energy
Drilling
drill rig/ concrete
Drilling
hand-held/
concrete
Drilling
hand-held/
masonry
Weight
Tool fixture
3.2
List of contents
Diamond core drill (1), with adapter for dust extraction (3), carrying case and instructions manual.
Special accessories: Elastic bore piercer
3.3
Sound emission and vibration acceleration
Sound emission values determined according to EN 60745-2-1.
The typical A-weighted sound pressure level is 88 dB(A).
The typical A-weighted sound capacity level is 99 dB(A).
Uncertainty K =3 dB.
Vibration total values a
Drilling into concrete: a
Hammer drilling into concrete: a
DME17DP
V
230
A
9,3
W
2000
W
1340
Hz
50 - 60
700 / 1700
1/min
14000 / 34000
0,4
Joule
0,1
mm
30-150
mm
30-100
mm
30-180
kg
5
(triax vector sum) and uncertainty K determined according to EN 60745-2-1:
h
2
= 5 m/s
, K=1,5 m/s
h,DD
= 8 m/s², K=1,5 m/s².
h,ID
DME17DP-L
230
9,3
2000
1340
50 - 60
540 / 1200
10800 / 24000
0,5
0,2
40-180
40-120
40-200
5
1 1/4" UNC
2
.
10
DME17DP-S
230
9,3
2000
1340
50 - 60
900 / 1700
16200 / 30600
0,3
0,2
30-100
30-100
30-120
5