Maintenance and inspection of the Magnetic Clamp
Regular maintenance and inspections are necessary to ensure the safe use and operation of the Magnetic Clamp.
Furthermore, country-specific standards and regulations must be observed depending upon user application.
The below maintenance intervals are classified according to the recommended schedule.
Before every use...
visually inspect the Magnetic Clamp for any damage
clean the magnetic contactarea of any contamination (i.e. rust, metal chips) that would cause unevenness
of attachment or an air gap between the workpiece
Weekly...
make sure the activation lever is not bent or the plastic of the activation lever is not cracked
make sure the activation lever springs into the locking notch when in the ON position
inspect the magnetic contact area for any protruding scratches, pressure point deformations, and/or
cracksinto the magnetic contactarea. Have the Magnetic Clamp repaired by the manufacturer if any
unevenness of the magnetic contact areasis identified.
Monthly...
check the markings and labeling on the Magnetic Clamp for legibility, damage, modification, or removal.To
meet full compliance, the entire Magnetic Clamp must be returned to the manufacture for calibration and
relabeling.
Annually...
have the load-bearing capacity of the Magnetic Clamp checked by the supplier or an authorized workshop,
should the application so require.
Unauthorized repairs or modification to the Magnetic Clamp are not permitted.
If you have any questions, please contact the manufacturer.
10