2. Place the Magnetic Clamp into the desired position on the workpiece, or place the workpiece onto the
Magnetic Clamp contact area.
Note: Although the Magnetic Clamp is in the OFF position, it still has a slight magnetic pre-
tensioning in order to avoid inadvertent slippage or dropping of the Magnetic Clamp, and/or the
workpiece (e.g. when used in a vertical or other forced position). This pre-tension also allows for
ease of positioning the Magnetic Clamp to the workpiece.
3. Align the workpiece and the Magnetic Clamp according to the desired application.
4. Rotate the Magnetic Clamp activation lever by 60° into the ON position. Always check to make sure the
lever springs into the locking notch.
5. Check both for a secure and strong hold of the magnetic contact area to the workpieces and that no
excessive air gap exists.
Important
DO NOT allow other ferromagnetic materials within 2 inches of any exposed ACTIVATED magnetic contact
area. Serious injury could occur from instantaneous magnetic attraction!
6. When the application is complete, deactivate the magnetic clamp and remove from the workpiece,
especially if the application might exceed the Maximum Operating Temperature of the Magnetic Clamp.
To deactivate the Magnetic Clamp, first lift the activation lever at its far end upwards to disengage the lever
from its latching notch (1) and return by 60°into the OFF position (2). Care must be taken because the
activation lever can quickly/strongly spring back to the OFF position when working on thin materials.