Descargar Imprimir esta página

KEKAI KT0584 Manual De Instrucciones página 9

Publicidad

Idiomas disponibles

Idiomas disponibles

A. Construction and characteristics
Transportable terrace/garden heater with tank housing
Casing in steel with powder-coating or stainless steel
Gas hose connections with metal clamp (screw caps for Germany)
Heat emission from reflector
B. Specifications
Use propane, butane or their mixtures gas only.
Max. wattage: 13000 watts
Min. wattage: 5000 watts
Consumption:
APPLIANCE CATEGORY:
TYPES OF GAS:
GAS PRESSURE:
OUTLET PRESSURE
OF REGULATOR:
Using the proper regulator according to outlet pressure of regulator as showed in the table above.
C. Table of injector
APPLIANCE CATEGORY:
TYPES OF GAS:
GAS PRESSURE:
TOTAL HEAT
INPUT
(Hs): (Qn)
INJECTOR SIZE:
The marking, for example, 1.90 on the injector,indicates that the size of injector is 1.90mm
The hose and regulator assembly must conform to local standard codes.
Regulator outlet pressure should meet the corresponding gas category in the table of injector.
The appliance requires approved hose in 1.4m length.
I
3+(28-30/37)
Butane
Propane
28-30mbar
37 mbar
30mbar
37 mbar
I
3+(28-30/37)
Butane
Propane
28-30mbar
37 mbar
13kW (G30:945g/h; G31:929g/h)
1.90 mm for main burner
0.18 mm for pilot burner
- 5 -
I
I
3B/P(30)
3B/P(50)
Butane, propane
Butane, propane
or their mixtures
or their mixtures
30 mbar
50mbar
30 mbar
50mbar
I
I
3B/P(50)
3B/P(30)
Butane, propane
Butane, propane
or their mixtures
or their mixtures
30 mbar
50mbar
1.70 mm for main burner
0.18 mm for pilot burner
I
3B/P(37)
Butane, propane
or their mixtures
37mbar
37mbar
I
3B/P(37)
Butane, propane
or their mixtures
37mbar
1.80 mm for main burner
0.18 mm for pilot burner

Publicidad

loading

Este manual también es adecuado para:

Kt0585Kt0586