SITE SELECTION
Select a site for the floor scale where it is least likely to
be damaged by forklifts and other material handling
devices. Floor scale load cell weighing elements are
prone to overload damage caused by side impacts,
falling objects and weight loads that exceed the rated
capacity of the scale.
Site should be:
• Level within 1/4".
• Free from vibration.
• Clean of debris.
• Out of the way of vehicle traffic patterns, unless
installed in a pit while having a rated capacity
that exceeds all loaded vehicle weights that could
possibly drive onto or contact the scale.
The cable from the floor scale to the digital weight
indicator should be run through conduit to protect it
against possible damage. Running the instrument cable
through conduit is the best method of protection.
UNPACKING
1. Inspect your shipment for damage. If you see visible
signs of damage, notify carrier at once.
2. Remove floor scale from the shipping pallet.
3. Unpack the digital indicator. Digital indicator and
power cord ship in a separate box.
PAGE 1 OF 18
1-800-295-5510
uline.com
INTRODUCTION
INTRODUCTION
RAMP INSTALLATION (OPTIONAL)
1. Set floor scale in a desired location.
2. Position the scale feet inside the mounting tabs.
3. Anchor the ramp to the floor using two 1/2 x 3"
Figure 1
HEIGHT AND LEVEL ADJUSTMENTS
1. Unlock the locknuts on all four feet.
2. Using a pry bar, lift the weight of the scale base off
3. Make adjustments by screwing the feet
4. Do not screw feet counterclockwise more than ten
5. Tighten locknuts on feet.
6. Check your work.
Pour le français, consulter les pages 13-18.
(See Figure 1)
anchors (not included).
Ramp
Load Cell Foot
the scale feet.
counterclockwise. All four feet should make firm
contact with the floor.
turns.
Para Español, vea páginas 7-12.
Mounting Tabs
Scale
Anchor goes here.
0622 IH-7935