4.3.3 E-## E/S digitales
º
Descripción del parámetro
Par. n
E-0#
E-00
Modo E/S digital
E-01
Terminal 18 entrada digital
E-02
Terminal 19 entrada digital
E-03
Terminal 27 entrada digital
E-04
Terminal 29 entrada digital
4
E-05
Terminal 32 entrada digital
E-06
Terminal 33 entrada digital
E-07
Terminal 37 parada segura
E-1#
E-10
Tiempo acel 2
E-11
Tiempo decel. 2
E-12
Tiempo acel 3
E-13
Tiempo decel. 3
E-14
Tiempo acel 4
E-15
Tiempo decel. 4
E-2#
E-20
Salida digital terminal 27
E-21
Salida digital terminal 29
E-24
Relé de función
E-26
Retardo conex., relé
E-27
Retardo desconex, relé
E-3#
E-30
Entrada digital Terminal X46/1
E-31
Entrada digital Terminal X46/3
E-32
Entrada digital Terminal X46/5
E-33
Terminal X46/7 Entrada digital
E-34
Entrada digital Terminal X46/9
E-35
Entrada digital Terminal X46/11
E-36
Entrada digital Terminal X46/13
E-5#
E-51
Terminal 27 modo E/S
E-52
Terminal 29 modo E/S
E-53
Terminal X30/2 entrada digital
E-54
Terminal X30/3 entrada digital
E-55
Terminal X30/4 entrada digital
E-56
Sal. dig. term. X30/6 (OPCGPIO)
E-57
Sal. dig. term. X30/7 (OPCGPIO)
E-6#
E-60
Term. 29 baja frecuencia
E-61
Term. 29 alta frecuencia
E-62
Term. 29 valor bajo ref. /realim.
E-63
Term. 29 valor alto ref. /realim.
E-64
Tiempo filtro pulsos constante #29
E-65
Term. 33 baja frecuencia
E-66
Term. 33 alta frecuencia
E-67
Term. 33 valor bajo ref. /realim.
E-68
Term. 33 valor alto ref. /realim.
E-69
Tiempo filtro pulsos constante #33
E-7#
E-70
Terminal 27 salida pulsos variable
E-72
Frec. máx. salida de pulsos #27
E-73
Termina 29 salida pulsos variable
E-75
Frec. máx. salida de pulsos #29
E-76
Terminal X30/6 var. salida pulsos
E-78
Frec. máx. salida de pulsos #X30/6
50
Valor predeterminado
4-ajustes
[0] PNP
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
[1] Alarma parada segura
1 set-up
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
0.01 s
All set-ups
0.01 s
All set-ups
[0] Sin función
All set-ups
[0] Sin función
All set-ups
[0] Sin función
All set-ups
[0] Sin función
All set-ups
[0] Sin función
All set-ups
[0] Sin función
All set-ups
[0] Sin función
All set-ups
[0] Entrada
All set-ups
[0] Entrada
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
100 Hz
All set-ups
100 Hz
All set-ups
0.000 ReferenceFeedbackUnit
All set-ups
ExpressionLimit
All set-ups
100 ms
All set-ups
100 Hz
All set-ups
100 Hz
All set-ups
0.000 ReferenceFeedbackUnit
All set-ups
ExpressionLimit
All set-ups
100 ms
All set-ups
null
All set-ups
ExpressionLimit
All set-ups
null
All set-ups
ExpressionLimit
All set-ups
null
All set-ups
ExpressionLimit
All set-ups
AF-650 GP Manual de funcionamiento
Cambio du-
Índice de
Tipo
rante el fun-
conversión
cionamiento
FALSE
-
Uint8
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-2
Uint32
TRUE
-2
Uint32
TRUE
-2
Uint32
TRUE
-2
Uint32
TRUE
-2
Uint32
TRUE
-2
Uint32
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-2
Uint16
TRUE
-2
Uint16
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
0
Uint32
TRUE
0
Uint32
TRUE
-3
Int32
TRUE
-3
Int32
FALSE
-3
Uint16
TRUE
0
Uint32
TRUE
0
Uint32
TRUE
-3
Int32
TRUE
-3
Int32
FALSE
-3
Uint16
TRUE
-
Uint8
TRUE
0
Uint32
TRUE
-
Uint8
TRUE
0
Uint32
TRUE
-
Uint8
TRUE
0
Uint32