Factory Settings - Phocos CIS-N-MPPT 100/30 Manual Del Usuario

Ocultar thumbs Ver también para CIS-N-MPPT 100/30:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 21
LFP Lithium Battery Wake-up Function
This charge controller is equipped with an LFP (LiFePO4) lithium battery wake-up feature. If lithium batteries are used
with this controller, they must have an integrated battery management system (BMS). The BMS typically provides
numerous safety features. When necessary, the BMS will shut-down the battery, electrically removing the battery from
this charge controller. When PV power is available, this CIS controller will attempt to "wake-up" the BMS when it detects
a disconnected battery by providing it with a current of approximately 100 mA, signalling that power is available for
charging. If the BMS wakes up successfully, the battery will provide voltage to the controller to resume normal operation
and allow charging. If wake-up is not successful, the controller will continually attempt to wake the battery up again in
increasingly longer intervals.
Ensure that no loads are directly connected to the battery for two reasons. First, this will interfere with the wake-up
function and will likely prevent the BMS from re-activating the battery. Second, if a load is directly connected to the
battery, it is likely the reason the BMS has had to intervene in the first place to prevent critical discharge. Therefore, ensure
all loads are connected to the load output of the controller or, if their current is too high (in the case of inverters for
example), connect these to the LFP battery only via a normally-open power relay or solid-state relay. The relay coil /
control side should then be powered by the controller load output.
Note: The connection of a relay to the output of a charge controller requires a free-wheeling diode in parallel to the load
output. Please pay attention to the polarity - the freewheeling diode must be connected in reverse polarity.
This way the CIS can control the load and avoid BMS intervention. Even if the BMS must disconnect the battery, the wake-
up feature can then wake the battery as necessary when PV power is available, without human intervention.

Factory Settings

You can configure CIS-N-MPPT 100/30 charge controllers via the Remote Control Unit (CIS-CU). See CIS-CU manual for
details.
Load mode
Low voltage disconnect
Battery type
Nightlight level
Load 1 evening hours
Load 1 morning hours
Dimming evening hours
Dimming morning hours
Dimming value
(1) PV panel open circuit voltage: Day level = Night level + 1.5/3.0 V
www.phocos.com
Factory setting
Standard controller (nightlight off)
SOC4
Gel
8.0/16.0 V (1)
0 h
0 h
0 h
0 h
50 %
1 6 |
P a g e

Publicidad

Tabla de contenido
loading

Tabla de contenido