method B: Sanitise accessories C1-C.2-C.3-C.4-C5-C6-C7-C8-C8.1-C8.2-C8.3-C9 by boiling them in water for 10 minutes;
use demineralised or distilled water to prevent limescale deposits.
method C: Sanitise accessories C1.1-C1.2-C1.3-C1.4-C2-C3-C4 with a hot steam steriliser for baby-bottles (not the micro-
wave type). Perform the process thoroughly following the instructions of the steriliser. To ensure the disinfection is effective,
choose a steriliser with an operating cycle of at least 6 minutes.
After disinfecting the accessories, shake them well and place them on a paper towel. Alternatively, dry them with a jet of
hot air (for example a hair dryer).
At the end of each use store the device with its accessories in a dry place away from dust. Do not store wet or
humid components, as this might lead to the formation of mould.
AIR FILTERING
The device is fitted with a suction filter, located inside the pressure adjustment knob,
which must be replaced when it is dirty or discoloured. To replace it, lift the intensity
adjustment Knob (A4) and extract the Filter.
Do not wash or reuse the same Filter. Regular Filter replacement is necessary to as-
sure proper compressor performance. The Filter must be regularly checked. Contact
your dealer or authorised service centre for replacement filters.
Note: Only use original accessories and spare parts by Flaem; we dis-
claim any liability in the event of using non original spare parts or accessories.

TROUBLESHOOTING

Switch off the device before any procedure and unplug the power cable from the socket.
PROBLEM
The motor does not work
Suction
is faint or imperceptible
Blocked float
If there is leakage
If, after checking the above-described conditions the device is still not working properly,
we recommend taking it to your trusted dealer or nearest authorised FLAEM service centre.
SOLUTION
Check the mains power.
Check that the plug of the power cable is well inserted in the mains socket and in the
socket on the back of the product.
Check that the device is switched on.
Disassemble and assemble the breast pump set again, following the instructions.
Check that all connections of the breast pump set and of the suction tube are securely
fastened.
Use the device in accordance with the instructions manual.
Ensure the breast shield fully adheres to the breast.
Ensure the flaps of the expression valve are closed.
Check that the valve and the membrane are clean and undamaged.
The ends of the tube must be securely fastened to the connector on the main body and
to the opening in the membrane's cover.
The diaphragm unit must be correctly assembled, as described in the instructions.
Do not twist or block the tube during expression.
All components must be completely dry.
Decrease the suction intensity level
Place the breast pump set in the appropriate bottle holder.
Switch off the device and disconnect the power cable from the socket.
Use a moist cloth (not wet) to clean the breast pump and the membrane area.
If there are visible residues, condensation or milk in the tube: clean all
the components of the breast pump set as described in the chapter "Cleaning and main-
tenance".
When the components are completely dry, assemble the breast pump kit once more.