check that the burner crown holes are
not obstructed.
7.6 Periodic maintenance
Speak to your local Authorised Service
Centre periodically to check the
8. TROUBLESHOOTING
WARNING!
Refer to Safety chapters.
8.1 What to do if...
Problem
There is no spark when
you try to activate the
spark generator.
The flame extinguishes im‐
mediately after ignition.
The flame ring is uneven.
The control panel bright‐
ness is reduced or it
switches off.
The control knob pilot
lights turn on after con‐
necting the hob to the
mains or after a power out‐
age.
Hob²Hood function does
not work.
conditions of the gas supply pipe and the
pressure adjuster, if fitted.
Possible cause
The hob is not connected
to an electrical supply or it
is connected incorrectly.
The fuse is blown.
Burner cap and crown are
placed incorrectly.
Thermocouple is not heat‐
ed up sufficiently.
Burner crown is blocked
with food residues.
The temperature of the
plate is high. To ensure
long lifetime of the display
the brightness is reduced
depending on the tempera‐
ture of the hob. Above a
certain temperature the
control panel switches off.
Pilot light test.
You covered the control
panel.
ENGLISH
Remedy
Check if the hob is correct‐
ly connected to the electri‐
cal supply.
Make sure that the fuse is
the cause of the malfunc‐
tion. If the fuse is blown
again and again, contact a
qualified electrician.
Place the burner cap and
crown correctly.
After lightning the flame,
keep the knob pushed for
equal or less than 10 sec‐
onds.
Make sure that the injector
is not blocked and the
burner crown is clean.
Let the hob cool down.
Refer to "Installation".
Remove the object from
the control panel.
21