WATER SOURCE
Autofill
1. When in autofill, the autofill icon flashes while unit is filling
with water.
2. The heater will start when water level reaches low-level sensor.
NOTE: If water does not reach the low-level sensor within
5 minutes, error code 6 flashes on screen. See Troubleshooting
section for details.
3. When water reaches temperature, unit will display READY along
with the set temperature.
NIGHT MODE
In Night Mode, unit will maintain water temperature at 158°F/70°C
during non-business hours to save energy and enable a quicker
heat-up time, so that hot water is ready when you need it. When
setting the time for Night Mode, you will be setting the time the unit
will be re-energized and will start heating the water to your pre-set
temperature (e.g., 5:00 am – unit will turn back on and start heating to
205°F).
1. SETTING TIME for NIGHT MODE
a. PRESS and hold
b. Use the
c. Once desired time is displayed, wait 10 seconds, and the
time will be set. Display will show set time and
3 seconds.
2. ENTERING/EXITING NIGHT MODE
a. Pressing
Saving Mode. Display will show the time of day and the
b. Unit will exit Night Mode and re-energize automatically
at the set time.
c. To exit out of
a. I f
press Start to re-energize the unit.
b. If
will automatically re-energize and start heating to set
temperature.
arrows to scroll to the desired time.
button once will enter into Night Mode/Energy
manually, press the
button for 2 seconds.
button is pressed to exit Night Mode, you must
button is pressed to exit Night Mode, unit
button for 2 seconds:
10
for
button or hold
.