Descargar Imprimir esta página

RedMax 96767210101 Manual Del Operador página 22

Publicidad

Idiomas disponibles

Idiomas disponibles

MAINTENANCE
IMPORTANT INFORMATION Do not open
or remove battery caps or covers. Adding or
checking level of electrolyte is not necessary.
Always use two wrenches for the terminal
screws.
CAUTION! Lead-acid batteries generate
explosive gases. Keep sparks, flame and
smoking materials away from batteries. Always
wear eye protection when around batteries.
Battery
If the battery is too weak to start the engine, it
must be recharged.
Jumper Cable Use
1. Connect each end of the RED cable to the
POSITIVE (+) terminal on each battery, taking
care not to short against chassis.
2. Connect one end of the BLACK cable to the
NEGATIVE (-) terminal of the fully charged
battery.
3. Connect the other end of the BLACK cable
to a good CHASSIS GROUND on the mower
with the discharged battery, away from the
fuel tank and battery.
To remove cables, reverse order
1. Remove BLACK cable first from chassis and
then from the fully charged battery.
2. Remove RED cable last from both batteries.
The mower is equipped with a maintenance
free battery and does not need servicing.
However, periodic charging of the battery with an
automotive type battery charger will extend its life.
• Keep battery and terminals clean.
• Keep battery bolts tight.
• See chart for charging times.
22
STD
STATE
BATTERY
OF
CHARGE
50 Amps
12.6V
100%
12.4V
75%
12.2V
50%
12.0V
25%
11.8V
0%
*Charging time depends on battery capacity,
condition, age, temperature and efficiency of charger
Cleaning battery and terminals
Corrosion and dirt on the battery and terminals
can cause the battery to lose power.
1. Loosen the two nuts attached to the side
J bolts just enough that the battery mount
bracket slides down off the battery.
2. Disconnect BLACK battery cable then RED
battery cable.
3. Carefully remove the battery from the mower
4. Rinse the battery with plain water and dry.
5. Clean terminals and battery cable ends with a
wire brush until shiny.
6. Coat the terminals with grease or petroleum
jelly.
Replacing battery
1. Install the new battery.
2. Connect RED battery cable first to positive (+)
battery terminal.
3. Connect BLACK grounding cable to negative
(-) battery terminal.
4. Slide mount bracket back up over battery and
tighten nuts.
5. Replace terminal boot cover.
APPROXIMATE CHARGING TIME*
TO FULL CHARGE AT 80
Maximum Rate at:
30 Amps
20 Amps
- FULL CHARGE -
20 min.
35 min.
48 min.
45 min.
75 min.
95 min.
65 min.
115 min.
145 min.
85 min.
150 min.
195 min.
F
O
10 Amps
90 min.
180 min.
280 min.
370 min.

Publicidad