4. Installation
1. Remove the screw of the battery cover of the main unit and install 1 x alkaline 9V battery (order code 6LR61,
not incl.). Note that this battery is used as backup in case of a power failure.
2. Plug the aerial into the jack and mount it in a vertical position. It is possible that the aerial is bent. Simply bend
it back.
3. Plug the AC adapter into the 9V socket.
4. Now, install the unit onto the wall if desired. Choose a suitable location,
at a height of 1.5 to 2m (5 to 6 feet). Drill the holes, install the plugs
and screws. Place the unit over the screws and slide securely the unit
over the screws (see fig.).
5. Setting the System
The system can only be set in standby mode. The device will automatically exit this setup mode after 15 seconds of
inactivity. Note that the HAM1000WS has a factory preset code (000) which can be changed into a personal code.
a. Changing the Access Code
1. Enter the factory preset access code (000). Press the PROG key once. PASSWORD will flash.
2. Press the ARM/DISARM key to confirm the will to modify the access code.
3. Enter your personal access code (3 to 6 digits) and press the ARM/DISARM key to confirm the new access
code.
4. Now press the DOWN or UP key to select a setup option or press the PROG key 5 times to exit.
NOTE: In case you forget your access code, hold PROG pressed and use a pen to press RESET
Release PROG. The system will restore to the factory preset access code (000) and reset date and time.
All other programmed settings will be maintained.
b. ID Codes
All the sensors and the remote control have a factory preset code. The whole system is ready for use. However,
you can expand the system by using use more sensors. To program a code into the unit, please follow these
steps:
1. Enter the access code and press PROG twice. You will see the LEARN icon flash on the LCD.
2. Press ARM/DISARM to confirm. The system will enter into the learning mode. The ZONE 1 icon will flash.
3. Press UP or DOWN to select the zone. A zone can either be coded (FULL) or empty (NO ID CODE). In the
first case, choose another zone or press DEL to delete the code. In the second case, a code can be
programmed.
4. Press ARM/DISARM to confirm the zone location.
5. Trigger the sensor of the motion detector or the door/window detector, or press any key on the remote control.
You will hear a long beep confirming the code has been successfully programmed.
6. Press UP or DOWN to select another zone to program or press PROG three times to exit.
c. Siren ON/OFF
1. To disable the siren, enter the access code and press PROG three times.
2. The
icon will flash on the LCD. Press ARM/DISARM to confirm.
3. Able or disable the siren using UP or DOWN. Press ARM/DISARM to confirm.
4. Press UP or DOWN to select another setup option or press PROG three times to exit.
HAM1000WS_v3
4
once.
VELLEMAN

Publicidad

loading