Descargar Imprimir esta página

Mitsubishi Electric NTYWST18A112A Serie Manual De Instrucciones página 10

Publicidad

Idiomas disponibles

Idiomas disponibles

● OPERATING INSTRUCTIONS ●
W
HEN YOU THINK THAT TROUBLE HAS OCCURRED
Even if these items are checked, when the unit does not recover from the
trouble, stop using the air conditioner and consult your dealer.
Symptom
Indoor Unit
The unit cannot be operated.
• Is the breaker turned on?
• Is the power supply plug connected?
• Is the ON timer set?
The horizontal vane does not
• Are the horizontal vanes installed cor-
move.
rectly?
• Is the fan guard deformed?
The unit cannot be operated
• This protects the unit according to instruc-
for about 3 minutes when
tions from the microprocessor. Please
restarted.
wait.
Mist is discharged from the air
• The cool air from the unit rapidly cools mois-
outlet of the indoor unit.
ture in the air inside the room, and it turns
into mist.
The swing operation of the
• This is for the swing operation of the HORI-
HORIZONTAL VANE is
ZONTAL VANE to be performed normally.
suspended for a while, then
restarted.
The airfl ow direction changes
• When the unit is operated in COOL or DRY
during operation.
mode, if the operation continues with air
The direction of the horizontal
blowing down for 0.5 to 1 hour, the direction
vane cannot be adjusted with
of the air fl ow is automatically set to upward
the remote controller.
position to prevent water from condensing
and dripping.
The unit starts operation by
• These models are equipped with an auto re-
itself when the main power is
start function. When the main power is turned
turned on, but hasn't received
off without stopping the unit with the remote
sign from the remote control-
controller and is turned on again, the unit
ler.
starts operation automatically in the same
mode as the one set with the remote control-
ler just before the shutoff of the main power.
Refer to "Auto restart function"
The indoor unit discolors over
• Although plastic turns yellow due to the infl u-
time.
ence of some factors such as ultraviolet light
and temperature, this has no effect on the
product functions.
Outdoor Unit
The fan of the outdoor unit
• When the outside temperature is low dur-
does not rotate even though
ing cooling operation, the fan operates
the compressor is running.
intermittently to maintain suffi cient cooling
Even if the fan starts to rotate,
capacity.
it stops soon.
Water leaks from the outdoor
• During COOL and DRY operations, pipe or
unit.
pipe connecting sections are cooled and this
causes water to condense.
Remote controller
The display on the remote
• Are the batteries exhausted?
controller does not appear or
• Is the polarity (+, -) of the batteries correct?
it is dim. The indoor unit does
Page 4
not respond to the remote
• Are any buttons on the remote controller of
control signal.
other electric appliances being pressed?
Does not cool
The room cannot be cooled
• Is the temperature setting appropriate?
suffi ciently.
Page 5
• Is the fan setting appropriate? Please change
fan speed to High or Super High.
• Are the fi lters clean?
• Is the fan or heat exchanger of the indoor
unit clean?
• Are there any obstacles blocking the air inlet
or outlet of the indoor or outdoor unit?
• Is a window or door open?
• When a ventilation fan or a gas cooker is
used in a room, the cooling load increases,
resulting in an insuffi cient cooling effect.
• When the outside temperature is high, the
cooling effect may not be suffi cient.
• It may take a certain time to reach the setting
temperature or may not reach that depend-
ing on the size of the room, the ambient
temperature, and the like.
En-9
Explanation & Check points
Page 7
page 5
.
Page 4
Page 6
Page 8
Symptom
Airfl ow
The air from the indoor unit
• Are the fi lters clean?
smells strange.
• Is the fan or heat exchanger of the indoor unit
clean?
• The unit may suck in an odor adhering to the
wall, carpet, furniture, cloth, etc. and blow it
out with the air.
Sound
Cracking sound is heard.
• This sound is generated by the expansion/
contraction of the front panel, etc. due to
change in temperature.
"Burbling" sound is heard.
• This sound is heard when the outside air is
absorbed from the drain hose by turning on
the range hood or the ventilation fan, making
water fl owing in the drain hose to spout out.
This sound is also heard when the outside air
blows into the drain hose in case the outside
wind is strong.
Mechanical sound is heard
• This is the switching sound in turning on/off
from the indoor unit.
the fan or the compressor.
The sound of water fl owing
• This is the sound of refrigerant or condensed
is heard.
water fl owing in the unit.
Hissing sound is sometimes
• This is the sound when the fl ow of refrigerant
heard.
inside the unit is changed.
In the following cases, stop using the air conditioner and consult your
dealer.
• When water leaks or drips from the indoor unit.
• When the upper operation indicator lamp blinks.
• When the breaker trips frequently.
• The remote control signal is not received in a room where an electronic ON/OFF
type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.
• Operation of the air conditioner interferes with radio or TV reception. An ampli-
fi er may be required for the affected device.
• When an abnormal sound is heard.
• When any refrigerant leakage is found.
Explanation & Check points
Page 8

Publicidad

loading