1. Before securing the plates supplied, establish the measurements using the data
provided in Table 1, in accordance with the wing opening angle.
2. Fix the motor support plates securely.
GATE WING OPENING ANGLE
Establish the required opening angle opportunely positioning the opening locks for the shutters.
Installation of mechanical limit stops.
At the open and closed positions of the sliding gate, it is recommended that mechanical limit stops are fitted which are able to stop the movement
of the gate during both opening and closing. Always follow the recommendations of the various relevant standards.
In the case of gates longer than 1.6 m the use of an elbow-bolt, type ZD06 (Fig. 3) or ZD26, with electric door lock Art. ZD04 (Fig. 3A) is recommended.