SPECIFICATIONS
• Weather resistant galvanized tank and low
temperatures.
• Gauge easy to read scale PSI and MPA.
• High pressure hose.
• High pressure connections.
• Ensuring constant pressure valve.
• Lever.
• Suction volume 45ml.
• Polyamide piston without distortion resistant to
friction and wear.
• Scales gauge easy to read and accurate scale in
PSI and Bar MPA.
• Connection R 1/2".
PERSONAL SAFETY
• Pump should be operated by trained personnel
only.
• Always wear safety goggles and gloves when
using the pump.
• Do not point the discharge end towards yourself
or anyone as there is potential hazard for
injection into skin / eyes.
• Never allow any part of the body to come in
contact with the operating fluid.
• Before operating the pump , check hose for signs
of wear , leaks or loose connections. If hose is
weak , worn or damaged, replace the hose
immediately.
• Incase of an accident, immediately seek
emergency medical attention. Do not try to treat
the injury yourself.
• Do not smoke when using / near the pump.
• Do not use the pump near a source of spark /
open flames etc.
OPERATION INSTRUCTIONS
This is a hand operated pump & must only be used
by hand force. Never use foot, hammer, pipe etc., to
operate the pump.
ATTENTION:
this
yourself with all operating features and safety
requirements.
USE:
1. Fill the tank with water.
2. Connect up the coupling to the network.
3. Close up the valve.
4. Pump up until reach the pressure test.
product,
familiarize
5. Hold up the line with pressure during test while.
6. Open up the valve allowing water ways.
ATTENTION: It is recommended that any
repairs or service are provided at a qualified
service center. Using clean grease will give you
years of trouble free use. Make sure that grease
use is not contaminated.
TROUBLESHOOTING
PROBLEM:
Loss of pressure or improperly pumping of the
testing pumps: When the testing pump shows an
effect of loss of pressure or improperly pumping,
because it is hard or it does not pump water, the
main reason used to be that the outlet valve is
blocked by impurities of water as lime, cement, dust
or other substances.
SOLUTION:
1. Disassemble the set of the outlet valve using a
5 mm hexagonal wrench. This "set of the outlet
valve" has four pices: O-ring gasket, plug, spring,
grooved stud.
2. Check that these four pieces are in good
conditions and clean any dirtiness they could have
(probably this dirtiness blocked the outlet valve).
3. Clean the place of the outlet valve using a
cylindrical brush or using compressed-air.
4. Assemble back the four pieces in the same way
screwing them on without forcing the spring, it
means, do not screw on to the end. If the spring
is forced, the flow of water will be blocked by it. A
correct adjust could be tested pumping water.
For adjusting the set of the outlet valve, it could
be screwing on until feel the spring power (do not
continue screwing on) and then loosen one or two
turns.
5. Pump water to check the correct adjustment of
the outlet valve.
• If the handle is too hard, loosen the outlet valve
using a 5 mm hexagonal wrench a little bit.
• If the valve loses pressure, screw on a little bit
this valve using a 5 mm hexagonal wrench.
E N G L I S H
3