Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• 73895000: The mixer can not used together with a
continuous flow water heater.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 38)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Maintenance (see page 40)
The check valves must be checked regularly according
to DIN EN 1717 in accordance with national or
regional regulations (at least once a year).
Fault
Mixer stiff
Mixer dripping
Water escaping at the threaded
base
Hot water temperature too low
4
English
Special accessories (order as an extra)
Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or after
max. 1 MPa
a prolonged period of non-use.
0,1 - 0,5 MPa
1,6 MPa
max. 70°C
65°C
max. 70°C / 4 min
Cause
- Cartridge defective, calcified
- Cartridge defective
- connection hoses not completely
screwed into basic body
- O-ring at the connection hose
defective.
- Hot water limiter incorrectly set
Assembly (see page 32)
Dimensions (see page 39)
Flow diagram (see page 40)
Spare parts (see page 43)
XXX = Colors
000 = Chrome Plated
800 = Stainless Steel Optic
extension #43333000 (see page 37)
Adapter (G⅜ / G½)
#93395000 (see page 44)
Cleaning (see page 41)
Operation (see page 45)
Test certificate (see page 48)
Remedy
- Exchange cartridge
- Exchange cartridge
- Tighten connection hoses by hand
- Exchange O-ring
- Set hot water limiter