OPERATION
Before performing a leak test, be sure that no sparks can occur and you are in a spacious outdoor
area. Connect the propane gas tank to the regulator and turn the valve on the unit to the "off"
position. Brush a soap and water mixture on all connections. Turn the gas supply on; if bubbles
occur on any connection there may be a leak. If you smell gas or a leak is discovered turn the
gas valve off, disconnect propane gas tank and do not use the appliance until the leak is
repaired.
Do not use the heating unit without inspecting the gas hose. If there are signs of wear or abrasion
you must replace the hose (if applicable). Pumice stones/lava rocks/LavaGlass
strike somebody's face during the process of lighting this unit; stand away from the unit for the first
20 minutes after igniting. Flame height should be a yellow/blue color between 2 - 10 inches in height.
Wait 50 minutes after extinguishing fame prior to placing a lid (if applicable) or protective cover on
heating item.
To Light
1. Make sure the control knob (F) is in the "off" position.
2. Open door (D) and slowly open the valve on the propane gas tank by turning the knob
counterclockwise.
3. Close the door (D) on the body (C).
4. A pulse igniter is built into the control knob (F) so pushing and truning the control knob (F)
counterclockwise to the "LOW" position will ignite the fuel.
5.
If ignition does not immediately take place in seconds, push and turn the control knob (F)
clockwise to "OFF" and wait 5 minutes, and then repeat the lighting procedure as above.
If igniter does not light burner, use a long match or long butane lighter.
6.
7.
Adjust ame to deisred ame with the control knob (F).
To Extinguish
1. Turn control knob (F) clockwise to the "LOW" position; let the knob pop up and continue turning
the control knob (F) to the "OFF" position.
2. Close the cylinder valve on the propane gas tank if you don't intend to use it for a long time.
could pop up and
®